Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Pump-flow-probe X-ray absorption spectroscopy as a tool for studying intermediate states of photocatalytic systems.

Smolentsev, G., Guda, A., Zhang, X., Haldrup, K., Andreiadis, E. S., Chayarot-Kerlidou, M., et al. (2013). Pump-flow-probe X-ray absorption spectroscopy as a tool for studying intermediate states of photocatalytic systems. Journal of Physical Chemistry C, 117(34), 17367-17375. doi:10.1021/jp4010554.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
2457084.pdf (Verlagsversion), 2MB
 
Datei-Permalink:
-
Name:
2457084.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (UNKNOWN id 303; )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
2457084_Suppl.pdf (Ergänzendes Material), 494KB
Name:
2457084_Suppl.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Smolentsev, G., Autor
Guda, A., Autor
Zhang, X., Autor
Haldrup, K., Autor
Andreiadis, E. S., Autor
Chayarot-Kerlidou, M., Autor
Canton, S. E.1, Autor           
Nachtegaal, M., Autor
Artero, V., Autor
Sundstrom, V., Autor
Affiliations:
1Research Group of Structural Dynamics of (Bio)Chemical Systems, MPI for Biophysical Chemistry, Max Planck Society, ou_578564              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: A new setup for pump-flow-probe X-ray absorption spectroscopy has been implemented at the SuperXAS beamline of the Swiss Light Source. It allows recording X-ray absorption spectra with a time resolution of tens of microseconds and high detection efficiency for samples with sub-millimolar concentrations. A continuous wave laser is used for the photoexcitation, with the distance between laser and X-ray beams and velocity of liquid flow determining the time delay, while the focusing of both beams and the flow speed profile define the time resolution. This method is compared with the alternative measurement technique that utilizes a 1 kHz repetition rate laser and multiple X-ray probe pulses. Such an experiment was performed at beamline 11ID-D of the Advanced Photon Source. Advantages, limitations, and potential for improvement of the pump-flow-probe setup are discussed by analyzing the photon statistics. Both methods with Co K-edge probing were applied to the investigation of a cobaloxime-based photocatalytic reaction. The interplay between optimizing for efficient photoexcitation and time resolution as well and the effect of sample degradation for these two setups are discussed.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2013-07-292013-08-29
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1021/jp4010554
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of Physical Chemistry C
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 117 (34) Artikelnummer: - Start- / Endseite: 17367 - 17375 Identifikator: -