Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Dependence of the hygroscopicity parameter κ on particle size, humidity and solute concentration: implications for laboratory experiments, field measurements and model studies

Wang, Z., Cheng, Y. F., Ma, N., Mikhailov, E. F., Pöschl, U., & Su, H. (2017). Dependence of the hygroscopicity parameter κ on particle size, humidity and solute concentration: implications for laboratory experiments, field measurements and model studies. Atmospheric Chemistry and Physics Discussions, 17.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Wang, Z.1, Autor           
Cheng, Y. F.1, Autor           
Ma, N.1, Autor           
Mikhailov, E. F.1, Autor           
Pöschl, U.1, Autor           
Su, H.1, Autor           
Affiliations:
1Multiphase Chemistry, Max Planck Institute for Chemistry, Max Planck Society, ou_1826290              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: The hygroscopicity parameter κ has been intensively used in the investigation of the water uptake, cloud condensation nuclei (CCN) activity and chemical composition of atmospheric aerosol particles. A representative value of κ is often assigned to individual species or sources. Such treatment may lead to confusion in closure studies of κ derived from hygroscopic growth factor measurements (κgf) and CCN activity measurements (κCCN), and in studies of aerosols at the sub-10 nm size range. Here we show that for particles of the same dry composition, κ may differ as a function of water content, solute concentration and particle size. The concentration- and size-dependence of κ are demonstrated for representative inorganic and organic compounds, i.e., ammonium sulfate (AS), sodium chloride (NaCl) and sucrose. Our results illustrate that an absolute closure between κgf and κCCN should not be expected, and how the deviations observed in field and laboratory experiments can be quantitatively explained and reconciled. The difference between κgf and κCCN increases as particle size decreases reaching up to 40 % and 30 % for 10 nm AS and NaCl particles, respectively. Moreover, we show that the deviations of κCCN vary from ~ 10 % for 30 nm and ~ 40 % for 200 nm, indicating a strong dependence on the Köhler models and thermodynamic parameterizations used for instrument calibration (e.g., effective water vapor supersaturation in CCN counter). By taking these factors into account, we can largely explain apparent discrepancies between κgf and κCCN values reported in the scientific literature. Our results help to understand and interpret κ values determined at different water vapor ratios and at different size ranges (especially sub-10 nm). We highlight the importance of self-consistent thermodynamic parameterizations when using AS for calibration aerosol and taking it as a reference substance representing inorganics in closure study between chemical composition and hygroscopicity of aerosol particles.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2017
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.5194/acp-2017-253
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Atmospheric Chemistry and Physics Discussions
  Kurztitel : Atmos. Chem. Phys. Discuss.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Katlenburg-Lindau, Germany : European Geophysical Society, Copernicus Publ.
Seiten: 22 Band / Heft: 17 Artikelnummer: - Start- / Endseite: - Identifikator: ISSN: 1680-7367
CoNE: https://pure.mpg.de/cone/journals/resource/111076360006006