English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Synchronization as a mechanism for low-energy anti-fibrillation pacing

Ji, Y. C., Uzelac, I., Otani, N., Luther, S., Gilmour, R. F., Cherry, E. M., et al. (2017). Synchronization as a mechanism for low-energy anti-fibrillation pacing. Heart Rhythm, 14(8), 1254-1262. doi:10.1016/j.hrthm.2017.05.021.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Ji, Y. C., Author
Uzelac, I., Author
Otani, N., Author
Luther, Stefan1, Author           
Gilmour, R. F., Author
Cherry, E. M., Author
Fenton, F. H., Author
Affiliations:
1Research Group Biomedical Physics, Max Planck Institute for Dynamics and Self-Organization, Max Planck Society, ou_2063288              

Content

show
hide
Free keywords: Defibrillation; Mechanism; Synchronization; Optical mapping
 Abstract: Low-energy anti-fibrillation pacing (LEAP) has been suggested as an alternative treatment in symptomatic fibrillation patients. It significantly lowers the energy required compared with standard 1-shock defibrillation. OBJECTIVE: In this study, we investigated the mechanism of arrhythmia termination by LEAP and systematically analyzed the influence of shock period and timing on the success rate of LEAP. METHODS: We induced atrial and ventricular fibrillation in isolated canine hearts and applied LEAP and standard 1-shock defibrillation to terminate the arrhythmia. We simulated the arrhythmia and LEAP using a 2-dimensional bidomain human atrial model. RESULTS: The ex vivo experiments showed successful termination of atrial fibrillation and ventricular fibrillation using LEAP, with an average 88% and 81% energy reduction, respectively, and both experiments and simulations verified that synchronization from virtual electrodes is the key mechanism for termination of arrhythmia by LEAP using modified Kuramoto phase plots and fraction of tissue excited (FTE) plots. We also observed in simulations that LEAP is more effective when the shock period is close to the dominant period and the first shock is delivered when FTE is decreasing. CONCLUSIONS: Our results support synchronization as the mechanism for arrhythmia termination by LEAP, and its effectiveness can be improved by adjusting shock period and timing.

Details

show
hide
Language(s): eng - English
 Dates: 2017-05-112017-08-08
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1016/j.hrthm.2017.05.021
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Heart Rhythm
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 14 (8) Sequence Number: - Start / End Page: 1254 - 1262 Identifier: -