日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Patch-clamp techniques for time-resolved capacitance measurements in single cells

Lindau, M., & Neher, E. (1988). Patch-clamp techniques for time-resolved capacitance measurements in single cells. Pflügers Archiv: European Journal of Physiology, 411(2), 137-146. doi:10.1007/BF00582306.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル
非表示: ファイル
:
BF00582306.pdf (出版社版), 2MB
 
ファイルのパーマリンク:
-
ファイル名:
BF00582306.pdf
説明:
-
OA-Status:
閲覧制限:
制限付き ( Max Planck Society (every institute); )
MIMEタイプ / チェックサム:
application/pdf
技術的なメタデータ:
著作権日付:
-
著作権情報:
-
CCライセンス:
-

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Lindau, M., 著者
Neher, E.1, 著者           
所属:
1Department of Membrane Biophysics, MPI for biophysical chemistry, Max Planck Society, ou_578579              

内容説明

表示:
非表示:
キーワード: -
 要旨: Two methods are described for estimation of passive cell parameters such as membrane capacitance, membrane conductance and access resistance in tight-seal whole cell recording. Both methods are restricted in their application to cases where the cell under study can be approximated by a simple three-component network with linear properties over some voltage range. One method, referred to as the time domain technique, requires only standard electrophysiological equipment and a computer. Parameters are derived from an analysis of capacitive transients during square wave stimulation. It is readily adaptable to wide variations in experimental parameters. Particurlarly, it is equally applicable to the “slow whole-cell” configuration (access resistance in the range 100 MΩ to 1 GΩ) and to normal whole-cell measurements (access resistance typically 10 MΩ). The other method applies a sine wave command signal to the cell and employs a lock-in amplifier to analyse the resulting current signal. Two modes of operating the lock-in amplifier are described. One mode provides an output signal directly proportional to small changes in capacitance at maximum resolution (1–10 fF). The other mode, in conjunction with a digital computer, supplies estimates of all passive cell parameters, as does the time domain technique, but with a large amount of data reduction performed by the lock-in amplifier itself. Due to the special hardware, however, this method is not as flexible as the time domain technique.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 1988-02
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): DOI: 10.1007/BF00582306
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Pflügers Archiv: European Journal of Physiology
  その他 : Pflügers Arch. Europ. J. Physiol.
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Heidelberg : Springer-Verlag
ページ: - 巻号: 411 (2) 通巻号: - 開始・終了ページ: 137 - 146 識別子(ISBN, ISSN, DOIなど): ISSN: 0031-6768
CoNE: https://pure.mpg.de/cone/journals/resource/954925432380