English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  GEOTRACES intercalibration of neodymium isotopes and rare earth element concentrations in seawater and suspended particles. Part 2: Systematic tests and baseline profiles

Pahnke, K., van de Flierdt, T., Jones, K. M., Lambelet, M., Hemming, S. R., & Goldstein, S. L. (2012). GEOTRACES intercalibration of neodymium isotopes and rare earth element concentrations in seawater and suspended particles. Part 2: Systematic tests and baseline profiles. Limnology and Oceanography: Methods, 10, 252-269.

Item is

Files

show Files
hide Files
:
Pahnke12.pdf (Publisher version), 2MB
Name:
Pahnke12.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Pahnke, K.1, Author           
van de Flierdt, T., Author
Jones, K. M., Author
Lambelet, M., Author
Hemming, S. R., Author
Goldstein, S. L., Author
Affiliations:
1Max Planck Research Group Marine Isotope Geochemistry, Max Planck Institute for Marine Microbiology, Max Planck Society, ou_2481707              

Content

show
hide
Free keywords: -
 Abstract: The large‐scale collection of seawater samples and analysis of trace elements and isotopes by the GEOTRACES program call for careful comparison and examination of different methods for sample collection, treatment, and processing. Here we report results for different filter types, sampling bottles, and preconcentration methods for Nd from seawater. Neodymium isotope ratios and concentrations of unfiltered and filtered seawater using five different filter types agree within 43‐56 ppm (2σ standard deviation, SD) and 10% (relative 2σ standard deviation), respectively. The filter choice therefore has no effect on the measured parameters at the studied locations in the western North Atlantic. This could well be different, however, in areas of high particle concentrations. We therefore strongly recommend filtration of seawater for Nd isotope and rare earth element concentration measurements. Dissolved 143Nd/144Nd ratios of seawater collected with Niskin bottles with internal nylon‐coated stainless steel springs and trace metal‐clean GO‐FLO bottles were the same within 43 ppm (2σ SD). The Niskin bottles used here are therefore suitable for the collection of seawater samples for the analysis of 143Nd/144Nd ratios. Iron coprecipitation and complexation with HDEHP/H2MEHP using C18 cartridges for the preconcentration of Nd from seawater yielded the same 143Nd/144Nd ratios within 37 ppm (2σ SD). Both methods are therefore appropriate. Water column profiles of 143Nd/144Nd ratios and Nd concentrations are reported for the North Atlantic (BATS) and North Pacific (SAFe), and profiles of all rare earth elements are reported for BATS. These baseline profiles are recommended for continued quality control and intercalibration by future GEOTRACES cruises.

Details

show
hide
Language(s): eng - English
 Dates: 2012-04
 Publication Status: Issued
 Pages: 18
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: eDoc: 634996
ISI: 000305062900005
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Limnology and Oceanography: Methods
  Other : Limnol. Oceanogr.: Methods
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Waco, Tex. : American Society of Limnology and Oceanography
Pages: - Volume / Issue: 10 Sequence Number: - Start / End Page: 252 - 269 Identifier: ISSN: 1541-5856
CoNE: https://pure.mpg.de/cone/journals/resource/991042728183802