  A novel radioactivity microsensor for high spatial resolution measurements of beta radiation

Filthuth, H., Eickert, G., Faerber, P., Jonkers, H. M., Polerecky, L., & de Beer, D. (2007). A novel radioactivity microsensor for high spatial resolution measurements of beta radiation. Limnology and Oceanography: Methods, 5, 309-316.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
Filthuth.pdf (Verlagsversion), 363KB
Name:
Filthuth.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Filthuth, H.1, Autor           
Eickert, G.1, Autor           
Faerber, P.2, Autor           
Jonkers, H. M.1, Autor           
Polerecky, L.1, Autor           
de Beer, D.1, Autor           
Affiliations:
1Permanent Research Group Microsensor, Max Planck Institute for Marine Microbiology, Max Planck Society, ou_2481711              
2Max Planck Institute for Marine Microbiology, Max Planck Society, ou_2481692              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: We developed a microsensor for the detection of β‐radiation with submillimeter spatial resolution. The microsensor consists of a scintillating sphere (diameter 100‐300 µm) glued to a tip of an optical fiber (core diameter 140 µm) enclosed in a thin glass capillary. The scintillating sphere was made by embedding YLu scintillation powder and TiO2 light scattering particles in a methacrylate matrix. Photons generated in the scintillator by the β‐particles are guided through the fiber and detected by a photomultiplier connected to the opposite fiber end. The photon counts generated by the photomultiplier are linearly proportional to the volume‐specific radioactivity in the sample. The background signal can be suppressed practically to zero if two fibers connected to two photomultipliers working in coincidence are used. This, however, results in slightly diminished sensor performance (lower sensitivity and signal‐to‐noise ratio). As examples of applications, the diffusion coefficients of 36Cl‐, H14CO3−, and 45Ca2+ in agar‐solidified saline water were measured, and the depth distribution of primary productivity in an intact microbial mat was determined from vertical profiles of 14C after incubation in the light using H14CO3− as tracer.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2007-10
 Publikationsstatus: Erschienen
 Seiten: 8
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: eDoc: 341970
ISI: 000251564500002
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Limnology and Oceanography: Methods
  Andere : Limnol. Oceanogr.: Methods
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Waco, Tex. : American Society of Limnology and Oceanography
Seiten: - Band / Heft: 5 Artikelnummer: - Start- / Endseite: 309 - 316 Identifikator: ISSN: 1541-5856
CoNE: https://pure.mpg.de/cone/journals/resource/991042728183802