English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Asymmetric nanofluidic grating detector for differential refractive index measurement and biosensing.

Purr, F., Bassu, M., Lowe, R. D., Thürmann, B., Dietzel, A., & Burg, T. P. (2017). Asymmetric nanofluidic grating detector for differential refractive index measurement and biosensing. Lab on a Chip, 17(24), 4265-4272. doi:10.1039/C7LC00929A.

Item is

Files

show Files
hide Files
:
2492020.pdf (Publisher version), 3MB
Name:
2492020.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-

Locators

show

Creators

show
hide
 Creators:
Purr, F.1, Author           
Bassu, M.1, Author           
Lowe, R. D.1, Author           
Thürmann, B., Author
Dietzel, A., Author
Burg, T. P.1, Author           
Affiliations:
1Research Group of Biological Micro- and Nanotechnology, MPI for Biophysical Chemistry, Max Planck Society, ou_578602              

Content

show
hide
Free keywords: -
 Abstract: Measuring small changes in refractive index can provide both sensitive and contactless information on molecule concentration or process conditions for a wide range of applications. However, refractive index measurements are easily perturbed by non-specific background signals, such as temperature changes or non-specific binding. Here, we present an optofluidic device for measuring refractive index with direct background subtraction within a single measurement. The device is comprised of two interdigitated arrays of nanofluidic channels designed to form an optical grating. Optical path differences between the two sets of channels can be measured directly via an intensity ratio within the diffraction pattern that forms when the grating is illuminated by a collimated laser beam. Our results show that no calibration or biasing is required if the unit cell of the grating is designed with an appropriate built-in asymmetry. In proof-of-concept experiments we attained a noise level equivalent to ∼10(-5) refractive index units (30 Hz sampling rate, 4 min measurement interval). Furthermore, we show that the accumulation of biomolecules on the surface of the nanochannels can be measured in real-time. Because of its simplicity and robustness, we expect that this inherently differential measurement concept will find many applications in ultra-low volume analytical systems, biosensors, and portable devices.

Details

show
hide
Language(s): eng - English
 Dates: 2017-10-242017
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1039/C7LC00929A
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Lab on a Chip
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 17 (24) Sequence Number: - Start / End Page: 4265 - 4272 Identifier: -