English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Stacked planar micro coils for single-sided NMR applications.

Watzlaw, J., Glöggler, S., Blümich, B., Mokwa, W., & Schnakenberg, U. (2013). Stacked planar micro coils for single-sided NMR applications. Journal of Magnetic Resonance, 230, 176-185. doi:10.1016/j.jmr.2013.02.013.

Item is

Files

show Files
hide Files
:
2525511.pdf (Publisher version), 2MB
 
File Permalink:
-
Name:
2525511.pdf
Description:
-
OA-Status:
Visibility:
Restricted (UNKNOWN id 303; )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Watzlaw, J., Author
Glöggler, S.1, Author           
Blümich, B., Author
Mokwa, W., Author
Schnakenberg, U., Author
Affiliations:
1Research Group of NMR Signal Enhancement, MPI for Biophysical Chemistry, Max Planck Society, ou_2396691              

Content

show
hide
Free keywords: -
 Abstract: This paper describes planar micro structured coils fabricated in a novel multilayer assembly for single-sided NMR experiments. By arranging the coil's turns in both lateral and vertical directions, all relevant coil parameters can be tailored to a specific application. To this end, we implemented an optimization algorithm based on simulations applying finite element methods (FEMs), which maximizes the coil's sensitivity and thus signal-to-noise ratio (SNR) while incorporating boundary conditions such as the coil's electrical properties and a localized sensitivity needed for single-sided applications. Utilizing thin-film technology and microstructuring techniques, the planar character is kept by a sub-millimeter overall thickness. The coils are adapted to the Profile NMR-MOUSE® magnet with a homogeneous slice of about 200 μm in height and a uniform depth gradient of about 20T/m. The final design of a coil with 20 turns, separated in four layers with five turns each, and an outer dimension of 4×4 mm(2) is able to measure a sample volume almost five times smaller than that of a state-of-the-art 14×16 mm(2) Profile NMR-MOUSE® coil with the same SNR. This allows for volume-limited measurements with high SNR and enables different future developments. The minimal dead time of 4 μs facilitates further improvements of the SNR by echo adding techniques and the characterization of samples with short T2 relaxation times. Measurements on solid polymers like polyethylene (PE) and polypropylene (PP) with T2 components as short as 200 μs approve the overall beneficial coil properties. Furthermore the ability to perform depth profiling with microscopic resolution is demonstrated.

Details

show
hide
Language(s): eng - English
 Dates: 2013-03-072013-05
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1016/j.jmr.2013.02.013
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Magnetic Resonance
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 230 Sequence Number: - Start / End Page: 176 - 185 Identifier: -