Deutsch
 
Benutzerhandbuch Datenschutzhinweis Impressum Kontakt
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Measurement of residual chemical shift anisotropies in compressed PMMA gels. Automatic compensation of gel isotropic shift contribution.

Hallwass, F., Teles, R. R., Hellemann, E., Griesinger, C., Gil, R. R., & Navarro-Vázquez, A. (2018). Measurement of residual chemical shift anisotropies in compressed PMMA gels. Automatic compensation of gel isotropic shift contribution. Magnetic Resonance in Chemistry, 56(5), 321-328. doi:10.1002/mrc.4711.

Item is

Basisdaten

einblenden: ausblenden:
Datensatz-Permalink: http://hdl.handle.net/21.11116/0000-0000-32B0-0 Versions-Permalink: http://hdl.handle.net/21.11116/0000-0001-1BAA-2
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
2526956.pdf (Verlagsversion), 836KB
 
Datei-Permalink:
-
Name:
2526956.pdf
Beschreibung:
-
Sichtbarkeit:
Eingeschränkt (Max Planck Institute for Biophysical Chemistry (Karl Friedrich Bonhoeffer Institute), Göttingen; )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
2526956_Suppl_1.docx (Ergänzendes Material), 7MB
Name:
2526956_Suppl_1.docx
Beschreibung:
-
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/vnd.openxmlformats-officedocument.wordprocessingml.document / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
2526956_Suppl_2.zip (Ergänzendes Material), 3MB
Name:
2526956_Suppl_2.zip
Beschreibung:
-
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/zip / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Hallwass, F.1, Autor              
Teles, R. R., Autor
Hellemann , E., Autor
Griesinger, C.1, Autor              
Gil, R. R., Autor
Navarro-Vázquez, A., Autor
Affiliations:
1Department of NMR-based Structural Biology, ou_578567              

Inhalt

einblenden:
ausblenden:
Schlagwörter: NMR; RCSAs; RDCs; aligning media; relative configuration
 Zusammenfassung: Mechanical compression of polymer gels provides a simple way for the measurement of Residual Chemical Shift Anisotropies (RCSAs), which then can be employed, on its own, or in combination with Residual Dipolar Couplings (RDCs), for structural elucidation purposes. RCSAs measured using compression devices needed a posteriori correction to account for the increase of the polymer to solvent ratio inside the swollen gel. This correction has been cast before in terms of a single free parameter which, as shown here, can be simultaneously optimized along with the components of the alignment tensor while still retaining discriminating power of the different relative configurations as illustrated in the stereochemical analysis of α-santonin and 10-epi-8-deoxycumambrin B.

Details

einblenden:
ausblenden:
Sprache(n): eng - Englisch
 Datum: 2018-01-112018-05
 Publikationsstatus: Im Druck publiziert
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1002/mrc.4711
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Chemistry
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 56 (5) Artikelnummer: - Start- / Endseite: 321 - 328 Identifikator: -