English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  A Test of Charge-Parity-Time Invariance at the Atto-Electronvolt Scale

Mooser, A., Higuchi, T., Smorra, C., Nagahama, H., Leefer, N., Schneider, G., et al. (2017). A Test of Charge-Parity-Time Invariance at the Atto-Electronvolt Scale. JPS conference proceedings, 18: 011019.

Item is

Basic

show hide
Genre: Conference Paper

Files

show Files

Locators

show
hide
Locator:
https://doi.org/10.7566/JPSCP.18.011019 (Publisher version)
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Mooser, Andreas1, Author
Higuchi, Takashi1, 2, Author
Smorra, Christian1, 3, Author
Nagahama, Hiroki1, 2, Author
Leefer, Nathan4, Author
Schneider, Georg1, 5, Author
Sellner, Stefan1, Author
Blaum, Klaus6, Author           
Matsuda, Yasuyuki2, Author
Quint, Wolfgang7, Author
Walz, Jochen4, 5, Author
Yamazaki, Yasunori8, Author
Ulmer, Stefan1, Author
Affiliations:
1Ulmer Initiative Research Unit, RIKEN, Saitama 351-0198, Japan, ou_persistent22              
2Graduate School of Arts and Sciences, University of Tokyo, Tokyo 153-8902, Japan, ou_persistent22              
3CERN, CH-1211 Geneva 23, Switzerland, ou_persistent22              
4Helmholz-Institut Mainz, Johann-Joachim-Becher-Weg 36, 55128 Mainz, Germany, ou_persistent22              
5Institut für Physik, Johannes Gutenberg-Universität Mainz, Staudingerweg 7, 55128 Mainz, Germany, ou_persistent22              
6Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society, ou_904548              
7Atomphysik, GSI-Helmholzzentrum für Schwerionenforschung, Planckstraße 1, 64291 Darmstadt, Germany, ou_persistent22              
8Atomic Physics Laboratory, RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198, Japan, ou_persistent22              

Content

show
hide
Free keywords: -
 MPINP: Präzisionsexperimente - Abteilung Blaum
 Abstract: We developed a novel fast measurement procedure for cyclotron frequency comparisons of two individual particles in a Penning trap, which enabled us to compare the charge-to-mass ratio of the proton and the antiproton with a fractional precision of 69 parts per trillion. To date this is the most precise test of charge-parity-time invariance using baryons. Our measurements were performed at cyclotron frequencies of about 30 MHz, which means that charge-parity-time symmetry holds at the atto-electronvolt scale.

Details

show
hide
Language(s): eng - English
 Dates: 2017-11-25
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.7566/JPSCP.18.011019
 Degree: -

Event

show
hide
Title: Conference on Low Energy Antiproton Physics (LEAP2016)
Place of Event: Kanazawa, Japan
Start-/End Date: 2016-03-06 - 2016-03-11

Legal Case

show

Project information

show

Source 1

show
hide
Title: JPS conference proceedings
  Abbreviation : J. Phys. Soc. Japan
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Tokyo : The Physical Society of Japan
Pages: - Volume / Issue: 18 Sequence Number: 011019 Start / End Page: - Identifier: CoNE: https://pure.mpg.de/cone/journals/resource/1