  Volumetric imaging with homogenised excitation and static field at 9.4 T

Tse, D., Wiggins, C., Ivanov, D., Brenner, D., Hoffmann, J., Mirkes, C., et al. (2016). Volumetric imaging with homogenised excitation and static field at 9.4 T. Magnetic Resonance Materials in Physics, Biology and Medicine, 29(3), 333-345. doi:10.1007/s10334-016-0543-6.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
Link (beliebiger Volltext)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Tse, DH, Autor
Wiggins, CJ, Autor
Ivanov, D, Autor
Brenner, D, Autor
Hoffmann, J1, 2, Autor           
Mirkes, C2, Autor           
Shajan, G2, Autor           
Scheffler, K1, 2, Autor           
Uludağ, K, Autor
Poser, BA, Autor
Affiliations:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
2Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Objectives To overcome the challenges of B0 and RF excitation inhomogeneity at ultra-high field MRI, a workflow for volumetric B0 and flip-angle homogenisation was implemented on a human 9.4 T scanner. Materials and methods Imaging was performed with a 9.4 T human MR scanner (Siemens Medical Solutions, Erlangen, Germany) using a 16-channel parallel transmission system. B0- and B1-mapping were done using a dual-echo GRE and transmit phase-encoded DREAM, respectively. B0 shims and a small-tip-angle-approximation kT-points pulse were calculated with an off-line routine and applied to acquire T1- and T 2 * -weighted images with MPRAGE and 3D EPI, respectively. Results Over six in vivo acquisitions, the B0-distribution in a region-of-interest defined by a brain mask was reduced down to a full-width-half-maximum of 0.10 ± 0.01 ppm (39 ± 2 Hz). Utilising the kT-points pulses, the normalised RMSE of the excitation was decreased from CP-mode’s 30.5 ± 0.9 to 9.2 ± 0.7 with all B 1 + voids eliminated. The SNR inhomogeneities and contrast variations in the T1- and T 2 * -weighted volumetric images were greatly reduced which led to successful tissue segmentation of the T1-weighted image. Conclusion A 15-minute B0- and flip-angle homogenisation workflow, including the B0- and B1-map acquisitions, was successfully implemented and enabled us to reduce intensity and contrast variations as well as echo-planar image distortions in 9.4 T images.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2016-06
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1007/s10334-016-0543-6
BibTex Citekey: TseWIBHMSSUP2016
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance Materials in Physics, Biology and Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 29 (3) Artikelnummer: - Start- / Endseite: 333 - 345 Identifikator: -