  17O relaxation times in the rat brain at 16.4 tesla

Wiesner, H., Balla, D., Shajan, G., Scheffler, K., Ugurbil, K., Chen, W., et al. (2016). 17O relaxation times in the rat brain at 16.4 tesla. Magnetic Resonance in Medicine, 75(5), 1886-1893. doi:10.1002/mrm.25814.

Item is

Basic

show hide
Item Permalink: http://hdl.handle.net/21.11116/0000-0000-79CC-3 Version Permalink: http://hdl.handle.net/21.11116/0000-0000-FA3A-6
Genre: Journal Article

Files

show Files

Locators

show
hide
Locator:
Link (Any fulltext)
Description:
-

Creators

show
hide
 Creators:
Wiesner, HM1, Author              
Balla, DZ1, 2, 3, Author              
Shajan, G1, Author              
Scheffler, K1, 2, Author              
Ugurbil, K, Author
Chen, W, Author
Uludag, K1, Author              
Pohmann, R1, 2, Author              
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
3Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497798              

Content

show
hide
Free keywords: -
 Abstract: Purpose Measurement of the cerebral metabolic rate of oxygen (CMRO2) by means of direct imaging of the 17O signal can be a valuable tool in neuroscientific research. However, knowledge of the longitudinal and transverse relaxation times of different brain tissue types is required, which is difficult to obtain because of the low sensitivity of natural abundance H217O measurements. Methods Using the improved sensitivity at a field strength of 16.4 Tesla, relaxation time measurements in the rat brain were performed in vivo and postmortem with relatively high spatial resolutions, using a chemical shift imaging sequence. Results In vivo relaxation times of rat brain were found to be T1 = 6.84 ± 0.67 ms and T2* = 1.77 ± 0.04 ms. Postmortem H217O relaxometry at enriched concentrations after inhalation of 17O2 showed similar T2* values for gray matter (1.87 ± 0.04 ms) and white matter, significantly longer than muscle (1.27 ± 0.05 ms) and shorter than cerebrospinal fluid (2.30 ± 0.16 ms). Conclusion Relaxation times of brain H217O were measured for the first time in vivo in different types of tissues with high spatial resolution. Because the relaxation times of H217O are expected to be independent of field strength, our results should help in optimizing the acquisition parameters for experiments also at other MRI field strengths.

Details

show
hide
Language(s):
 Dates: 2016-05
 Publication Status: Published in print
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Method: -
 Identifiers: DOI: 10.1002/mrm.25814
BibTex Citekey: WiesnerBSSUCUP2015
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 75 (5) Sequence Number: - Start / End Page: 1886 - 1893 Identifier: -