English
 
User Manual Privacy Policy Disclaimer Contact us
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Three-layered radio frequency coil arrangement for sodium MRI of the human brain at 9.4 Tesla

Shajan, G., Mirkes, C., Buckenmaier, K., Hoffmann, J., Pohmann, R., & Scheffler, K. (2016). Three-layered radio frequency coil arrangement for sodium MRI of the human brain at 9.4 Tesla. Magnetic Resonance in Medicine, 75(2), 906-916. doi:10.1002/mrm.25666.

Item is

Basic

show hide
Item Permalink: http://hdl.handle.net/21.11116/0000-0000-7A36-B Version Permalink: http://hdl.handle.net/21.11116/0000-0000-FA36-A
Genre: Journal Article

Files

show Files

Locators

show
hide
Locator:
Link (Any fulltext)
Description:
-

Creators

show
hide
 Creators:
Shajan, G1, Author              
Mirkes, C1, Author              
Buckenmaier, K1, 2, Author              
Hoffmann, J1, 2, Author              
Pohmann, R1, 2, Author              
Scheffler, K1, 2, Author              
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: Purpose A multinuclei imaging setup with the capability to acquire both sodium (23Na) and proton (1H) signals at 9.4 Tesla is presented. The main objective was to optimize coil performance at the 23Na frequency while still having the ability to acquire satisfactory 1H images. Methods The setup consisted of a combination of three radio frequency (RF) coils arranged in three layers: the innermost layer was a 27-channel 23Na receive helmet which was surrounded by a four-channel 23Na transceiver array. The outer layer consisted of a four-channel 1H dipole array for B0 shimming and anatomical localization. Transmit and receive performance of the 23Na arrays was compared to a single-tuned 23Na birdcage resonator. Results While the transmit efficiency of the 23Na transceiver array was comparable to the birdcage, the 23Na receive array provided substantial signal-to-noise ratio (SNR) gain near the surface and comparable SNR in the center. The utility of this customized setup was demonstrated by 23Na images of excellent quality. Conclusion High SNR, efficient transmit excitation and B0 shimming capability can be achieved for 23Na MRI at 9.4T using novel coil combination. This RF configuration is easily adaptable to other multinuclei applications at ultra high field (≥ 7T).

Details

show
hide
Language(s):
 Dates: 2016-02
 Publication Status: Published in print
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Method: -
 Identifiers: DOI: 10.1002/mrm.25666
BibTex Citekey: ShajanMBHPS2015
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 75 (2) Sequence Number: - Start / End Page: 906 - 916 Identifier: -