English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Combination of a multimode antenna and TIAMO for traveling-wave imaging at 9.4 Tesla

Hoffmann, J., Mirkes, C., Shajan, G., Scheffler, K., & Pohmann, R. (2016). Combination of a multimode antenna and TIAMO for traveling-wave imaging at 9.4 Tesla. Magnetic Resonance in Medicine, 75(1), 452-462. doi:10.1002/mrm.25614.

Item is

Files

show Files

Locators

show
hide
Locator:
Link (Any fulltext)
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Hoffmann, J1, 2, Author           
Mirkes, C1, 2, Author           
Shajan, G1, 2, Author           
Scheffler, K1, 2, Author           
Pohmann, R1, 2, Author           
Affiliations:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
2Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Content

show
hide
Free keywords: -
 Abstract: Purpose
To investigate the performance of a multimode antenna combined with time-interleaved acquisition of modes (TIAMO) for improved 1H image homogeneity as compared to conventional traveling-wave imaging in the human brain at 9.4 Tesla (T).
Methods
An adjustable three-port antenna was built to stimulate the propagation of three basic waveguide modes within a 9.4 T scanner bore. For TIAMO, two time-interleaved acquisitions using different linear combinations of these modes were optimized to achieve a homogeneous rooted sum-of-squares combination of their inline image patterns ( inline image). The antenna's transmit and receive performance, as well as local specific absorption rate, were analyzed using experiments and numerical simulations.
Results
The optimized TIAMO inline image combination was superior to radiofrequency shimming. Across the entire brain, it improved the homogeneity of the excitation field by a factor of two and its maximum-to-minimum ratio by almost a factor of five as compared to the circularly polarized mode. The two-fold increase in “virtual” receive channels enhanced the parallel imaging performance and enabled the use of higher acceleration factors.
Conclusion
Despite the limited number of channels, a remote three-port antenna combined with TIAMO represents an easily implementable setup to achieve void-free 1H images from the entire brain at 9.4 T, which can be used for anatomical localization and B0 shimming.

Details

show
hide
Language(s):
 Dates: 2016-01
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.25614
BibTex Citekey: HoffmannMSSP2015
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Wiley-Liss
Pages: - Volume / Issue: 75 (1) Sequence Number: - Start / End Page: 452 - 462 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149