日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  In vivo metabolite quantification using ERETIC with corrections for changes in the RF transmission and recepetion field

Zoelch, N., Hock, A., Avdievich, N., & Henning, A. (2016). In vivo metabolite quantification using ERETIC with corrections for changes in the RF transmission and recepetion field. Poster presented at 24th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2016), Singapore.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0000-7BA3-E 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0000-ECB1-E
資料種別: ポスター

ファイル

表示: ファイル

関連URL

表示:
非表示:
URL:
Link (全文テキスト(全般))
説明:
-
OA-Status:

作成者

表示:
非表示:
 作成者:
Zoelch, N, 著者
Hock, A, 著者
Avdievich, NI1, 2, 3, 著者           
Henning, A1, 2, 3, 著者           
所属:
1Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_2528692              
2Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
3Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

内容説明

表示:
非表示:
キーワード: -
 要旨: With ERETIC (Electric Reference To access In vivo Concentrations) metabolite signals measured in vivo are referenced to a signal measured in a phantom while directly correcting for differences in the coli loading conditions between the in vivo and in vitro measurement. This is beneficial compared to using an internal reference because no assumption about the concentration or the relaxation rate of the internal reference is need. However in contrast to the signal of an internal reference the ERETIC signal contains no information about B1 during transmission or reception and changes in B1 between the in vivo and in vitro measurement or at different positions are misinterpreted as metabolite concentration changes. The aim of this work was to tackle this problem by incorporating reception sensitivity corrections into the ERETIC method and by using a volume based power optimization to avoid differences during transmission. As a result, the obtained metabolite concentrations agree well with the values obtained with internal water referencing in healthy volunteers.

資料詳細

表示:
非表示:
言語:
 日付: 2016-05-11
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): BibTex参照ID: ZoelchHAH2016
 学位: -

関連イベント

表示:
非表示:
イベント名: 24th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2016)
開催地: Singapore
開始日・終了日: -

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: 24th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2016)
種別: 会議論文集
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: - 通巻号: 3990 開始・終了ページ: - 識別子(ISBN, ISSN, DOIなど): -