  A quantitative and accelerated R1q-based polymer gel dosimetry evaluation for dose verification in radiotherapy

Mann, P., Schuenke, P., Zaiss, M., Witte, M., Mueller, S., Ladd, M., et al. (2016). A quantitative and accelerated R1q-based polymer gel dosimetry evaluation for dose verification in radiotherapy. Magnetic Resonance Materials in Physics, Biology and Medicine, 29(Supplement 1), S195-S196.

Item is

Basic

show hide
Genre: Meeting Abstract

Files

show Files

Locators

show
hide
Locator:
Link (Publisher version)
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Mann, P, Author
Schuenke, P, Author
Zaiss, M1, 2, Author           
Witte, M, Author
Mueller, S, Author
Ladd, ME, Author
Bachert, P, Author
Karger, C, Author
Affiliations:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
2Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Content

show
hide
Free keywords: -
 Abstract: Purpose/Introduction: A very promising tool for 3D dose verification in radiotherapy is represented by polymer gel dosimetry (PGD) utilizing MRI. Nonetheless, due to very long acquisition times (Tacq.) using the standard multi spin-echo (multi-SE) evaluation, this method is not used for standard dose verification yet. In this study, we prove the feasibility of an evaluation employing on-resonant R1q, the socalled relaxation rate in the rotating frame, which leads to significantly reduced Tacq. Subjects and Methods: The used PAGAT dosimetry gel consists of monomers, embedded within a gelatin matrix that starts to polymerize after irradiation1. This polymerization process results in a dose-dependent increase of the relaxation rate R2, which was evaluated by MRI (Biograph mMR, Siemens, Germany) using a 2D multi-SE sequence (32 echoes, TE = 40 ms, TR = 6 s, resolution 0.5 9 0.5 mm2, Tacq. = 25:36 min). The spin-lock sequence used for determination of R1q consists of a tip-down pulse, followed by a locking pulse cluster (max. locking time 255 ms), and a subsequent tip-up pulse. Tipping pulses are realized using adiabatic half-passage pulses for improved B1-insensitivity. Image readout was realized using a HASTE2 sequence (32 locking times, TR = 12 s, 0.5x0.5 mm2, Tacq. = 6:36 min). For irradiation with 6 MV photons from a linear accelerator (Artiste, Siemens, Germany), a small spherical dose distribution (3 coplanar and equally–spaced 1x1 cm2- fields) located completely within the gel container was administered. For dose calibration eight gel containers were irradiated with known doses of 0–7 Gy. Results: The calibration curves can be described by a mono-exponential function (Fig. 1). Converting the R2- and R1q-images by means of this calibration curve into a dose-image revealed a clearly visible focal dose distribution with steep gradients as exemplarily shown for R2 in Fig. 2. Quantitative comparison of measured and calculated dose distributions showed a good agreement of 92.1 for R2-based and 98.1 for R1q-based evaluation using the 2D-gamma index criteria for 3 mm/3 3. The dose profiles through a sagittal slice (red line in Fig. 2) are shown in Figure 3. Discussion/Conclusion: We could show that R1q-mapping is a feasible tool for accelerated quantitative PGD dose measurement. As the global spin-lock preparation can be combined with every conventional 3D-MRI readout (e.g., EPI) it is possible to acquire a 3Dvolume within the same acquisition time. This leads to an additional acceleration factor as the multi-SE measurement time increases linearly with the number of slices. To further improve R1q-based PGD measurement, both dosimetry gels recipe and spin-lock preparation need to be perfectly tuned which is currently under investigation.

Details

show
hide
Language(s):
 Dates: 2016-09-30
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1007/s10334-016-0569-9
BibTex Citekey: MannSZWMLBK2016
 Degree: -

Event

show
hide
Title: 33rd Annual Scientific Meeting of the European Society for Magnetic Resonance in Medicine and Biology (ESMRMB 2016)
Place of Event: Wien, Austria
Start-/End Date: -

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance Materials in Physics, Biology and Medicine,
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 29 (Supplement 1) Sequence Number: - Start / End Page: S195 - S196 Identifier: -