English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  SAR and scan-time optimized 3D whole-brain double inversion recovery imaging at 7T

Pracht, E., Feiweier, T., Ehses, P., Brenner, D., Roebroeck, A., Weber, B., et al. (2018). SAR and scan-time optimized 3D whole-brain double inversion recovery imaging at 7T. Magnetic Resonance in Medicine, 79(5), 2620-2628. doi:10.1002/mrm.26913.

Item is

Files

show Files

Locators

show
hide
Locator:
Link (Publisher version)
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Pracht, ED, Author
Feiweier, T, Author
Ehses, P1, 2, Author           
Brenner, D, Author
Roebroeck, A, Author
Weber, B, Author
Stöcker, T, Author
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: Purpose The aim of this project was to implement an ultra-high field (UHF) optimized double inversion recovery (DIR) sequence for gray matter (GM) imaging, enabling whole brain coverage in short acquisition times ( math formula5 min, image resolution 1 mm3). Methods A 3D variable flip angle DIR turbo spin echo (TSE) sequence was optimized for UHF application. We implemented an improved, fast, and specific absorption rate (SAR) efficient TSE imaging module, utilizing improved reordering. The DIR preparation was tailored to UHF application. Additionally, fat artifacts were minimized by employing water excitation instead of fat saturation. Results GM images, covering the whole brain, were acquired in 7 min scan time at 1 mm isotropic resolution. SAR issues were overcome by using a dedicated flip angle calculation considering SAR and SNR efficiency. Furthermore, UHF related artifacts were minimized. Conclusion The suggested sequence is suitable to generate GM images with whole-brain coverage at UHF. Due to the short total acquisition times and overall robustness, this approach can potentially enable DIR application in a routine setting and enhance lesion detection in neurological diseases.

Details

show
hide
Language(s):
 Dates: 2017-092018-05
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.26913
BibTex Citekey: PrachtFEBRWS2017
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 79 (5) Sequence Number: - Start / End Page: 2620 - 2628 Identifier: -