  Respiratory motion prediction and prospective correction for free-breathing arterial spin-labeled perfusion MRI of the kidneys

Song, H., Ruan, D., Liu, W., Stenger, V., Pohmann, R., Fernández-Seara, M., Nair, T., Jung, S., Luo, J., Motai, Y., Ma, J., Hazle, J., & Gach, H. (2017). Respiratory motion prediction and prospective correction for free-breathing arterial spin-labeled perfusion MRI of the kidneys. Medical Physics, 44(3), 962-973. doi:10.1002/mp.12099.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0000-C331-C 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0000-F9CC-2
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:
非表示:
URL:
Link (全文テキスト(全般))
説明:
-
OA-Status:

作成者

表示:
非表示:
 作成者:
Song, H, 著者
Ruan, D, 著者
Liu, W, 著者
Stenger, VA, 著者
Pohmann, R1, 2, 著者           
Fernández-Seara, MA, 著者
Nair, T, 著者
Jung, S, 著者
Luo, J, 著者
Motai, Y, 著者
Ma, J, 著者
Hazle, JD, 著者
Gach, HM, 著者
所属:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

内容説明

表示:
非表示:
キーワード: -
 要旨: Purpose Respiratory motion prediction using an artificial neural network (ANN) was integrated with pseudocontinuous arterial spin labeling (pCASL) MRI to allow free-breathing perfusion measurements in the kidney. In this study, we evaluated the performance of the ANN to accurately predict the location of the kidneys during image acquisition. Methods A pencil-beam navigator was integrated with a pCASL sequence to measure lung/diaphragm motion during ANN training and the pCASL transit delay. The ANN algorithm ran concurrently in the background to predict organ location during the 0.7-s 15-slice acquisition based on the navigator data. The predictions were supplied to the pulse sequence to prospectively adjust the axial slice acquisition to match the predicted organ location. Additional navigators were acquired immediately after the multislice acquisition to assess the performance and accuracy of the ANN. The technique was tested in eight healthy volunteers. Results The root-mean-square error (RMSE) and mean absolute error (MAE) for the eight volunteers were 1.91 ± 0.17 mm and 1.43 ± 0.17 mm, respectively, for the ANN. The RMSE increased with transit delay. The MAE typically increased from the first to last prediction in the image acquisition. The overshoot was 23.58 ± 3.05 using the target prediction accuracy of ± 1 mm. Conclusion Respiratory motion prediction with prospective motion correction was successfully demonstrated for free-breathing perfusion MRI of the kidney. The method serves as an alternative to multiple breathholds and requires minimal effort from the patient.

資料詳細

表示:
非表示:
言語:
 日付: 2017-03
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1002/mp.12099
BibTex参照ID: SongRLSPFNJLMMHG2017_2
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Medical Physics
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 44 (3) 通巻号: - 開始・終了ページ: 962 - 973 識別子(ISBN, ISSN, DOIなど): -