  Desynchronization of Cartesian k-space sampling and periodic motion for improved retrospectively self-gated 3D lung MRI using quasi-random numbers

Weick, S., Völker, M., Hemberger, K., Meyer, C., Ehses, P., Polat, B., Breuer, F., Blaimer, M., Fink, C., Schad, L., Sauer, O., Flentje, M., & Jakob, P. (2017). Desynchronization of Cartesian k-space sampling and periodic motion for improved retrospectively self-gated 3D lung MRI using quasi-random numbers. Magnetic Resonance in Medicine, 77(2), 787-793. doi:10.1002/mrm.26159.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0000-C335-8 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0000-C336-7
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:
非表示:
URL:
Link (全文テキスト(全般))
説明:
-
OA-Status:

作成者

表示:
非表示:
 作成者:
Weick, S, 著者
Völker, M, 著者
Hemberger, K, 著者
Meyer, C, 著者
Ehses, P1, 著者           
Polat, B, 著者
Breuer, FA, 著者
Blaimer, M, 著者
Fink, C, 著者
Schad, LR, 著者
Sauer, OA, 著者
Flentje, M, 著者
Jakob, PM, 著者
所属:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

内容説明

表示:
非表示:
キーワード: -
 要旨: Purpose To demonstrate that desynchronization between Cartesian k-space sampling and periodic motion in free-breathing lung MRI improves the robustness and efficiency of retrospective respiratory self-gating. Methods Desynchronization was accomplished by reordering the phase (ky) and partition (kz) encoding of a three-dimensional FLASH sequence according to two-dimensional, quasi-random (QR) numbers. For retrospective respiratory self-gating, the k-space center signal (DC signal) was acquired separately after each encoded k-space line. QR sampling results in a uniform distribution of k-space lines after gating. Missing lines resulting from the gating process were reconstructed using iterative GRAPPA. Volunteer measurements were performed to compare quasi-random with conventional sampling. Patient measurements were performed to demonstrate the feasibility of QR sampling in a clinical setting. Results The uniformly sampled k-space after retrospective gating allows for a more stable iterative GRAPPA reconstruction and improved ghost artifact reduction compared with conventional sampling. It is shown that this stability can either be used to reduce the total scan time or to reconstruct artifact-free data sets in different respiratory phases, both resulting in an improved efficiency of retrospective respiratory self-gating. Conclusion QR sampling leads to desynchronization between repeated data acquisition and periodic respiratory motion. This results in an improved motion artifact reduction in shorter scan time.

資料詳細

表示:
非表示:
言語:
 日付: 2017-02
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1002/mrm.26159
BibTex参照ID: WeickVHMEPBBFSSFJ2016
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance in Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 77 (2) 通巻号: - 開始・終了ページ: 787 - 793 識別子(ISBN, ISSN, DOIなど): -