日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Simultaneous mapping of water shift and B1(WASABI)-Application to field-Inhomogeneity correction of CEST MRI data

Schuenke, P., Windschuh, J., Roeloffs, V., Ladd, M., Bachert, P., & Zaiss, M. (2017). Simultaneous mapping of water shift and B1(WASABI)-Application to field-Inhomogeneity correction of CEST MRI data. Magnetic Resonance in Medicine, 77(2), 571-580. doi:10.1002/mrm.26133.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0000-C345-6 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0000-C799-3
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:
非表示:
URL:
Link (全文テキスト(全般))
説明:
-
OA-Status:

作成者

表示:
非表示:
 作成者:
Schuenke, P, 著者
Windschuh, J, 著者
Roeloffs, V, 著者
Ladd, ME, 著者
Bachert, P, 著者
Zaiss, M1, 著者           
所属:
1German Cancer Research Center (DKFZ), Medical Physics in Radiology, Im Neuenheimer Feld 280, D–69120 Heidelberg, Germany, ou_persistent22              

内容説明

表示:
非表示:
キーワード: -
 要旨: Purpose Together with the development of MRI contrasts that are inherently small in their magnitude, increased magnetic field accuracy is also required. Hence, mapping of the static magnetic field (B0) and the excitation field (B1) is not only important to feedback shim algorithms, but also for postprocess contrast-correction procedures. Methods A novel field-inhomogeneity mapping method is presented that allows simultaneous mapping of the water shift and B1 (WASABI) using an off-resonant rectangular preparation pulse. The induced Rabi oscillations lead to a sinc-like spectrum in the frequency-offset dimension and allow for determination of B0 by its symmetry axis and of B1 by its oscillation frequency. Results Stability of the WASABI method with regard to the influences of T1, T2, magnetization transfer, and repetition time was investigated and its convergence interval was verified. B0 and B1 maps obtained simultaneously by means of WASABI in the human brain at 3 T and 7 T can compete well with maps obtained by standard methods. Finally, the method was applied successfully for B0 and B1 correction of chemical exchange saturation transfer MRI (CEST-MRI) data of the human brain. Conclusion The proposed WASABI method yields a novel simultaneous B0 and B1 mapping within 1 min that is robust and easy to implement.

資料詳細

表示:
非表示:
言語:
 日付: 2017-02
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1002/mrm.26133
BibTex参照ID: SchuenkeWRLBZ2016
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance in Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 77 (2) 通巻号: - 開始・終了ページ: 571 - 580 識別子(ISBN, ISSN, DOIなど): -