English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  The necessity of parametrizing macromolecules for accurate quantification of ultra-short TE and TR 1H FID MRSI data at 9.4T

Nassirpour, S., Chang, P., & Henning, A. (2017). The necessity of parametrizing macromolecules for accurate quantification of ultra-short TE and TR 1H FID MRSI data at 9.4T. Poster presented at 34th Annual Scientific Meeting of the European Society for Magnetic Resonance in Medicine and Biology (ESMRMB 2017), Barcelona, Spain.

Item is

Files

show Files

Locators

show
hide
Locator:
Link (Publisher version)
Description:
-

Creators

show
hide
 Creators:
Nassirpour, S1, 2, Author              
Chang, P1, 2, Author              
Henning, A1, 2, Author              
Affiliations:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
2Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_2528692              

Content

show
hide
Free keywords: -
 Abstract: Purpose/Introduction: At ultra-short TE and TR, macromolecule quantification becomes extremely important [1, 2], because of shorter relaxation times and thus lower saturation, these molecules contribute greatly to the spectrum. Measuring the MMs and including them as a single baseline might not be enough because of regional and relaxation time differences between the different macromolecule components [1, 2]. In this work, we measured and modelled individual macromolecule components at 9.4T. We then used our proposed MM model to highlight the necessity of parametrizing the individual macromolecule components for ultra-short TE and TR MRSI measurements. Subjects and Methods: 8 healthy subjects were scanned on a 9.4T Siemens whole-body human scanner. Metabolite-nulled data using DIR [1] were acquired and used to model the MM baseline. The T1 of these metabolites in gray and white matter were estimated using variable flip angle method on MRSI datasets acquired at 4 different flip angles with a TR of 500 ms. High resolution (3.25mm 9 3.25mm 9 10 mm) ultra-short TE 1H FID MRSI [3–6] data with two different TRs of 300 ms and 500 ms were also collected. These data were fitted using LCMODEL [7] with three different MM baseline models (‘‘no MM’’, ‘‘measured MM’’ as an average single-component MM baseline model, and our proposed multi-component ‘‘modelled MM’’ shown in Figure 1a). Results: Figure 1 shows our proposed MM model along with the estimated T1 values. Figure 2 shows the metabolite maps resulting from fitting the datasets acquired at TR = 300 ms with 3 different models for 2 different volunteers. Figure 3 shows a boxplot of how much the metabolite concentrations are overestimated when different models are used. The difference between the two different TRs are due to saturation effects that have not been corrected for. However, the figure highlights how using different MM models on each TR can account for the macromolecule saturation effects. Discussion/Conclusion: Figure 1 shows that there are regional and relaxation time differences between individual macromolecule components that cause metabolite concentrations to differ from the no MM model to various degrees (as shown in Figure 2). Figure 3 further shows that if a single MM baseline is used in fitting, depending on the TR, the concentration of metabolite will be underestimated to varying degrees, since different macromolecule components relax at different rates. Also, due to regional differences, the overestimation degree varies between white and gray matter. The only way to account for all of this is to use a parametrized MM model like the one we have proposed.

Details

show
hide
Language(s):
 Dates: 2017-10-21
 Publication Status: Published in print
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1007/s10334-017-0634-z
BibTex Citekey: NassirpourCH2017_6
 Degree: -

Event

show
hide
Title: 34th Annual Scientific Meeting of the European Society for Magnetic Resonance in Medicine and Biology (ESMRMB 2017)
Place of Event: Barcelona, Spain
Start-/End Date: -

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance Materials in Physics, Biology and Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 30 (Supplement 1) Sequence Number: - Start / End Page: S473 - S474 Identifier: -