日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Improving performance of linear field generation with multi-coil setup by optimizing coils position

Aghaeifar, A., Loktyushin, A., Eschelbach, M., & Scheffler, K. (2017). Improving performance of linear field generation with multi-coil setup by optimizing coils position. Poster presented at 34th Annual Scientific Meeting of the European Society for Magnetic Resonance in Medicine and Biology (ESMRMB 2017), Barcelona, Spain.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0000-C3FB-9 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0000-FA6C-E
資料種別: ポスター

ファイル

表示: ファイル

関連URL

表示:
非表示:
URL:
Link (出版社版)
説明:
-
OA-Status:

作成者

表示:
非表示:
 作成者:
Aghaeifar, A1, 2, 著者           
Loktyushin, A2, 3, 著者           
Eschelbach, M1, 2, 著者           
Scheffler, K1, 2, 著者           
所属:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
2Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
3Dept. Empirical Inference, Max Planck Institute for Intelligent Systems, Max Planck Society, ou_1497647              

内容説明

表示:
非表示:
キーワード: -
 要旨: Purpose/Introduction: Recent publications[1],[2] report a high capability of a multi-coil setup to generate equivalent linear fields. Hence, the spatial encoding which is performed by scanner’s built-in linear gradient, can be accomplished with a multi-coil setup and therefore can be used for imaging in parallel with shimming[3]. The accuracy of the linear field produced by multi-coil is the benchmark key factor. Increasing the number of individual coils brings more degrees of freedom and a better generation of linear fields with the cost of a more complex setup to fabricate and maintain. Here, it is demonstrated how optimization of coil position results in generating superior linear fields with a limited number of coils. Subjects and Methods: Recent reports[1],[2] have used 48 and 84 coils which were arranged with a layout of 6*8 and 6*14 respectively. For comparison, we simulated a local multi-coil setup with 16, 24, 32, 48 and 84 circular shaped coils. All coils are placed on a cylinder with a diameter/length of 360/300 mm which is large enough to house an RF coil. We used optimization-based search of coil positions that result in three linear orthogonal fields for the FOV of 200*200*200 mm around the isocenter. Simulation started from arranging individual coils in a regular fashion on the cylinder surface. The magnetic field for each coil was calculated using the Biot–Savart law with no constraint for the floating current in the coils. The optimization was performed using the fmincon function in MATLAB. Results: As an initial position for the optimization, we placed the coils in a symmetric configuration such that they cover the whole cylinder surface. Figure 1 shows the arrangement of 16 individual coils before and after optimization to produce the linear field. Figure 2 demonstrates a comparison between the ideal linear fields, the generated linear field from 16 symmetrically positioned coils and the generated linear fields from 16 position-optimized coils. Figure 3 illustrates how position optimization can improve the quality of the linear fields generated by a multi-coil setup. As a cost function, we used cross-correlation between optimized field and the ideal linear field and also the l2-norm of their difference. Discussion/Conclusion: According to Fig. 3, position optimized arrangement for 16, 24 and 32 coils can bring the same or even better quality compared to the symmetric arrangement for 32, 48 and 84 coils respectively. This proves the importance of the optimal coil configuration to acquire high fidelity linear field with less coils.

資料詳細

表示:
非表示:
言語:
 日付: 2017-10-20
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1007/s10334-017-0633-0
BibTex参照ID: AghaeifarLES2017
 学位: -

関連イベント

表示:
非表示:
イベント名: 34th Annual Scientific Meeting of the European Society for Magnetic Resonance in Medicine and Biology (ESMRMB 2017)
開催地: Barcelona, Spain
開始日・終了日: -

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance Materials in Physics, Biology and Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 30 (Supplement 1) 通巻号: - 開始・終了ページ: S259 - S259 識別子(ISBN, ISSN, DOIなど): -