  Optimized adiabatic spin-lock pulses for robust dynamic glucose enhanced MRI at 3T

Herz, K., Zaiss, M., & Scheffler, K. (2017). Optimized adiabatic spin-lock pulses for robust dynamic glucose enhanced MRI at 3T. Poster presented at 34th Annual Scientific Meeting of the European Society for Magnetic Resonance in Medicine and Biology (ESMRMB 2017), Barcelona, Spain.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0000-C3FF-5 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0000-C400-2
資料種別: ポスター

ファイル

表示: ファイル

関連URL

表示:
非表示:
URL:
Link (全文テキスト(全般))
説明:
-
OA-Status:

作成者

表示:
非表示:
 作成者:
Herz, K1, 2, 著者           
Zaiss, M1, 2, 著者           
Scheffler, K1, 2, 著者           
所属:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
2Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

内容説明

表示:
非表示:
キーワード: -
 要旨: Purpose/Introduction: Adiabatic spin-lock (SL) was shown to enable dynamic glucose enhanced (DGE) imaging at 7T [1–3]. While the proposed pulses are robust against B1 inhomogeneity the mismatch between adiabatic and locking pulses (Fig. 1a) is in principle prone to B0 artifacts. To robustly translate the adiabatic SL to clinical field strength of 3T we want to improve the stability in the presence of B0 inhomogeneity by matching the RF amplitude of tipping and locking pulse. To achieve this a lower (and shorter) adiabatic tilting pulse is proposed and tested in vivo. Subjects and Methods: Simulation. In addition to the commonly used hyperbolic secant (HS) adiabatic pulse [4], we introduced a Blackman windowed HS amplitude modulation in combination with an exponential frequency modulation (HSExp pulse), defined by the maximum amplitude B1, the bandwidth Df, the exponential parameter l, the length of the Blackman window twindow and the pulse duration tadia. Using a compiled Bloch simulation as a mex file in MATLAB, trajectory computation of the adiabatic pulse was performed for more than 380000 different parameter settings: 1 B l B 80; 5 lT B B1 B 15 lT; 500 Hz B Df B 5000 Hz; 0 ms B twindow B 3 ms; 1 ms B tadia B 10 ms. Imaging Imaging of three healthy volunteers was performed on a 3 T MRI scanner (PRISMA, Siemens), using the optimized HSExp pulse, as well as the HS pulses [1]. On resonant SL-prepared imaging consists of an adiabatic SL pulse cluster (Fig. 1a) and a subsequent single-shot centric-spiral reordered 3D GRE readout (680 k-space lines, FA = 6, TE= 1.95 ms, TR = 3.95 ms, Grappa = 2, elliptical scanning, BW = 700 Hz/px, resolution 1.6 9 1.6 9 3 mm3, FOV = 17 9 21 9 4.8 cm3). Results: The optimized HSExp pulse (l = 51; B1 = 7 lT; Df = 4000 Hz; twindow = 2.8 ms; tadia = 5 ms) found by Bloch simulations has a much smaller discontinuity of 2 lT than the HS pulse with 15 lT (Fig. 1a). The simulated magnetization trajectory reveals good performance of the adiabatic SL independent of typical B0 deviations (Fig. 1b). In vivo, also flat T1q -weighted images could be measured with significantly reduced duration and amplitude of the tip pulses (Figs. 2, 3).

資料詳細

表示:
非表示:
言語:
 日付: 2017-10-19
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1007/s10334-017-0632-1
BibTex参照ID: HerzZS2017
 学位: -

関連イベント

表示:
非表示:
イベント名: 34th Annual Scientific Meeting of the European Society for Magnetic Resonance in Medicine and Biology (ESMRMB 2017)
開催地: Barcelona, Spain
開始日・終了日: -

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance Materials in Physics, Biology and Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 30 (Supplement 1) 通巻号: - 開始・終了ページ: S87 - S88 識別子(ISBN, ISSN, DOIなど): -