日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Inflated false positive rates in fMRI depend on the voxel size of normalized images

Mueller, K., Lepsien, J., Möller, H., & Lohmann, G. (2017). Inflated false positive rates in fMRI depend on the voxel size of normalized images. Poster presented at 23rd Annual Meeting of the Organization for Human Brain Mapping (OHBM 2017), Vancouver, BC, Canada.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0000-C45F-9 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0000-C460-6
資料種別: ポスター

ファイル

表示: ファイル

関連URL

表示:
非表示:
URL:
Link (全文テキスト(全般))
説明:
-
OA-Status:

作成者

表示:
非表示:
 作成者:
Mueller, K, 著者
Lepsien, J, 著者
Möller, H, 著者
Lohmann, G1, 2, 著者           
所属:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

内容説明

表示:
非表示:
キーワード: -
 要旨: Introduction: In a recent manuscript, Eklund et al. (2016) reported inflated false positive rates in functional magnetic resonance imaging (fMRI) using common software packages. Here, we would like to draw attention to an important aspect that was not addressed in this publication. Specifically, we note that statistical inferences obtained using the Gauss random field approach depend heavily on a pre-processing parameter that was not included in the analysis performed by Eklund et al. (2016), namely the spatial resolution to which the data are resampled and interpolated during pre-processing. This resampling is needed to align the data to a common anatomical template. Eklund et al. used the common default setting of 2×2×2 mm³. In response to the paper by Eklund et al., Flandin and Friston (2016) used a different setting of this parameter, namely 3×3×3 mm³. Together with a more stringent initial cluster-forming threshold, they did not observe inflated false positive rates. However, a spatial resolution of 2×2×2 mm³ is the default value in two major software packages (SPM, FSL) and, hence, it is likely to be used for processing fMRI data by these packages. Moreover, in previous work, Friston and colleagues (Hopfinger et al., 2000) stated that resampling to 2×2×2 mm³ renders the analysis "more sensitive". It is, thus, unclear what a valid setting for this parameter should be. Therefore, it is of substantial relevance to systematically assess its influence on statistical inference. Methods: We analyzed 47 resting-state fMRI data sets, each acquired at a spatial resolution of 3×3×4 mm³ with 300 volumes. Using a strategy analogous to Eklund et al. (2016) we imposed various fake designs including block- and event-related types. Analysis was performed using SPM12. Normalization included a resampling with three different voxel sizes: 3×3×3 mm³, 2×2×2 mm³, and 1×1×1 mm³. Using a family-wise error (FWE) correction for multiple comparisons based on the Gauss Random Field approach, we first evaluated each data set separately. Thereafter, we performed a group-level inference in which all 47 data sets were pooled. Results: On the individual level, we found that with higher resampling resolutions, the FWE-corrected p-values decrease systematically so that more and more false positives occur. Table 1 shows coordinates and p-values of two different clusters obtained by statistical analysis of resting-state fMRI data using an arbitrary on/off-design with a block length of 20 s. As expected by our null hypothesis, we did not obtain any positive clusters with 3×3×3 mm³ resolution. However, with 2×2×2 mm³, the p-values are already smaller leading to a significant cluster. With a resolution of 1×1×1 mm³, both clusters are significant. Figure 1 shows the same effect using a fake event-related design with two experimental conditions. In the group analysis, we also observed that the FWE-corrected p-values decreased systematically with higher resampling resolutions. Noise clusters became significant when using a smaller voxel size after normalization. Conclusions: It appears that there is a systematic dependence of the false positive rate on the resampling parameter with smaller voxel sizes leading to smaller FWE-corrected p-values and hence more false positives. While some dependence on pre-processing parameters may be inevitable, a systematic dependence of this type is clearly worrisome, because researchers may be tempted to interpolate their data until the desired statistical significance level is reached. Statistical inference should certainly not depend in such a systematic way on a pre-processing parameter that can be set ad libitum. Clearly, this issue requires further in-depth analysis.

資料詳細

表示:
非表示:
言語:
 日付: 2017-06-28
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): BibTex参照ID: MuellerLML2017_2
 学位: -

関連イベント

表示:
非表示:
イベント名: 23rd Annual Meeting of the Organization for Human Brain Mapping (OHBM 2017)
開催地: Vancouver, BC, Canada
開始日・終了日: -

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: 23rd Annual Meeting of the Organization for Human Brain Mapping (OHBM 2017)
種別: 会議論文集
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: - 通巻号: 4112 開始・終了ページ: - 識別子(ISBN, ISSN, DOIなど): -