日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Flexible gradient driver system for a multi-coil shim setup: design considerations and implementation

Aghaeifar, A., Zivkovic, I., Steffen, T., Mirkes, C., & Scheffler, K. (2017). Flexible gradient driver system for a multi-coil shim setup: design considerations and implementation. Magnetic Resonance Materials in Physics, Biology and Medicine, 30(Supplement 1), S50-S51.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0000-C53E-D 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0000-C53F-C
資料種別: 会議抄録

ファイル

表示: ファイル

関連URL

表示:
非表示:
URL:
Link (全文テキスト(全般))
説明:
-
OA-Status:

作成者

表示:
非表示:
 作成者:
Aghaeifar, A1, 2, 著者           
Zivkovic, I2, 著者           
Steffen, T1, 著者           
Mirkes, C2, 著者           
Scheffler, K1, 2, 著者           
所属:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
2Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

内容説明

表示:
非表示:
キーワード: -
 要旨: Purpose/Introduction: Recent studies have demonstrated the high potential of local, multi-coil shim setups to mitigate B0 field inhomogeneities through dynamic and global shimming[1][2]. For this approach, each coil needs an individually controllable current driver. The drivers must be able to supply a stable and reproducible current with a minimal power dissipation. Here, we demonstrate a 32-channel, low-cost, modular current driver that can source/sink up to 5A per channel and 120A in total to drive a wide range of inductive loads. Subjects and Methods: The amplifier core is mostly designed based on the Howland current source[3]. The circuit (Fig. 1a) is programmable during runtime by the user, which makes it adaptable for different inductive loads. Each channel comprises a pair of OPA549 high-current op-amps to push and pull the current to the load. A current sense resistor of 0.1X is series with the output to make simultaneous current feedback control and real-time monitoring possible. The power supply for each amplifier can be adjusted through a custom-made GUI. The user can also set an offset for each channel output to compensate for any current drift. The input for the amplifier is generated by a PXIe–6738 unit, a high-density analog output module, and first passes through a PID controller. The parameters of the PID controller are adjustable through the GUI to obtain the best performance for different loads. We packed two drivers into one module (Fig. 1b) that can be readily mounted/dismounted in an amplifier rack. Results: We used our amplifier to drive a home-built 16-channel multi-coil shim setup [1] inside a 9.4 T MR scanner. We applied a range of currents from -2A to +2A and in reverse order with a step size of 0.25A and acquired a B0 map to evaluate the drivers’ output characteristics. The drivers’ output linearity and hysteresis (Table 1) were evaluated by fitting a linear model to the measured B0 maps. After adjusting the PID parameters, a rise time of 50us was achieved by measuring the step response with a load of 128lH (Fig. 2a) while the coil was in the scanner’s bore. Enabling the driver and running a gradient-echo sequence resulted in a maximum current disturbance of 40 mA (Fig. 2b). No artifacts could be detected in the acquired images when the drivers were connected to the coil. Figure 2 Driver performance test; a) a rise time of 50us was achieved with a load of 200 lH; b) maximum current disturbance of 40 mA resulted when running GRE sequence Discussion/Conclusion: A 32-channel flexible modular multi-coil driver was constructed and evaluated successfully. Several safety regulations (thermal, current limit, voltage limit, etc.) are considered in design with adjustable margins.

資料詳細

表示:
非表示:
言語:
 日付: 2017-10-19
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1007/s10334-017-0632-1
BibTex参照ID: AghaeifarZSMS2017
 学位: -

関連イベント

表示:
非表示:
イベント名: 34th Annual Scientific Meeting of the European Society for Magnetic Resonance in Medicine and Biology (ESMRMB 2017)
開催地: Barcelona, Spain
開始日・終了日: -

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance Materials in Physics, Biology and Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 30 (Supplement 1) 通巻号: - 開始・終了ページ: S50 - S51 識別子(ISBN, ISSN, DOIなど): -