Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Photobleaching in STED nanoscopy and its dependence on the photon flux applied for reversible silencing of the fluorophore

Oracz, J., Westphal, V., Radzewicz, C., Sahl, S. J., & Hell, S. W. (2017). Photobleaching in STED nanoscopy and its dependence on the photon flux applied for reversible silencing of the fluorophore. Scientific Reports, 7: 11354, pp. 1-14. doi:10.1038/s41598-017-09902-x.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
ScientificRep_7_2017_11354.pdf (beliebiger Volltext), 6MB
 
Datei-Permalink:
-
Name:
ScientificRep_7_2017_11354.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (Max Planck Institute for Medical Research, MHMF; )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
https://www.nature.com/articles/s41598-017-09902-x.pdf (beliebiger Volltext)
Beschreibung:
-
OA-Status:
externe Referenz:
https://doi.org/10.1038/s41598-017-09902-x (beliebiger Volltext)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Oracz, Joanna, Autor
Westphal, Volker, Autor
Radzewicz, Czesław, Autor
Sahl, Steffen J., Autor
Hell, Stefan W.1, Autor           
Affiliations:
1Optical Nanoscopy, Max Planck Institute for Medical Research, Max Planck Society, ou_2364730              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: In STED (stimulated emission depletion) nanoscopy, the resolution and signal are limited by the fluorophore de-excitation efficiency and photobleaching. Here, we investigated their dependence on the pulse duration and power of the applied STED light for the popular 750 nm wavelength. In experiments with red- and orange-emitting dyes, the pulse duration was varied from the sub-picosecond range up to continuous-wave conditions, with average powers up to 200 mW at 80 MHz repetition rate, i.e. peak powers up to 1 kW and pulse energies up to 2.5 nJ. We demonstrate the dependence of bleaching on pulse duration, which dictates the optimal parameters of how to deliver the photons required for transient fluorophore silencing. Measurements with the dye ATTO647N reveal that the bleaching of excited molecules scales with peak power with a single effective order ~1.4. This motivates peak power reduction while maintaining the number of STED-light photons, in line with the superior resolution commonly achieved for nanosecond STED pulses. Other dyes (ATTO590, STAR580, STAR635P) exhibit two distinctive bleaching regimes for constant pulse energy, one with strong dependence on peak power, one nearly independent. We interpret the results within a photobleaching model that guides quantitative predictions of resolution and bleaching.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2017-05-102017-08-012017-09-122017
 Publikationsstatus: Erschienen
 Seiten: 14
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1038/s41598-017-09902-x
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Scientific Reports
  Kurztitel : Sci. Rep.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: London, UK : Nature Publishing Group
Seiten: - Band / Heft: 7 Artikelnummer: 11354 Start- / Endseite: 1 - 14 Identifikator: ISSN: 2045-2322
CoNE: https://pure.mpg.de/cone/journals/resource/2045-2322