Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Quality assessment of MEG-to-MRI coregistrations

Sonntag, H., Haueisen, J., & Maess, B. (2018). Quality assessment of MEG-to-MRI coregistrations. Physics in Medicine and Biology, 63(7): 075003. doi:10.1088/1361-6560/aab248.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Sonntag, Hermann1, Autor           
Haueisen, Jens2, Autor
Maess, Burkhard1, Autor           
Affiliations:
1Methods and Development Group MEG and EEG - Cortical Networks and Cognitive Functions, MPI for Human Cognitive and Brain Sciences, Max Planck Society, Leipzig, DE, ou_2205650              
2Institute for Biomedical Engineering and Informatics, TU Ilmenau, Germany, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: For high precision in source reconstruction of magnetoencephalography (MEG) or electroencephalography data, high accuracy of the coregistration of sources and sensors is mandatory. Usually, the source space is derived from magnetic resonance imaging (MRI). In most cases, however, no quality assessment is reported for sensor-to-MRI coregistrations. If any, typically root mean squares (RMS) of point residuals are provided. It has been shown, however, that RMS of residuals do not correlate with coregistration errors. We suggest using target registration error (TRE) as criterion for the quality of sensor-to-MRI coregistrations. TRE measures the effect of uncertainty in coregistrations at all points of interest. In total, 5544 data sets with sensor-to-head and 128 head-to-MRI coregistrations, from a single MEG laboratory, were analyzed. An adaptive Metropolis algorithm was used to estimate the optimal coregistration and to sample the coregistration parameters (rotation and translation). We found an average TRE between 1.3 and 2.3 mm at the head surface. Further, we observed a mean absolute difference in coregistration parameters between the Metropolis and iterative closest point algorithm of $(1.9 \pm 15){\hspace{0pt}}^{\circ}$ and $(1.1 \pm 9)$ m. A paired sample t-test indicated a significant improvement in goal function minimization by using the Metropolis algorithm. The sampled parameters allowed computation of TRE on the entire grid of the MRI volume. Hence, we recommend the Metropolis algorithm for head-to-MRI coregistrations.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2017-10-112018-02-262018-03-222018-04
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1088/1361-6560/aab248
PMID: 29480813
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Physics in Medicine and Biology
  Andere : Phys. Med. Biol.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: London? : IOP Pub.
Seiten: - Band / Heft: 63 (7) Artikelnummer: 075003 Start- / Endseite: - Identifikator: ISSN: 0031-9155
CoNE: https://pure.mpg.de/cone/journals/resource/954925433410