Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  An 8-Channel Transceive Head Coil Array for 7T

Yazdanbakhsh, P., Resmer, F., Cavusoglu, M., Henning, A., & Lanz, T. (2013). An 8-Channel Transceive Head Coil Array for 7T. Magnetic Resonance Materials in Physics, Biology and Medicine, 26(Supplement 1), 345-346.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Meeting Abstract

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
Link (Verlagsversion)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Yazdanbakhsh, P, Autor
Resmer, F, Autor
Cavusoglu, M, Autor           
Henning, A1, 2, Autor           
Lanz, T, Autor
Affiliations:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
2Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_2528692              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Purpose/Introduction: In this study we present an optimized 8-channel transmit-receive head coil array to achieve maximum B1 efficiency and minimum SAR for brain imaging at 7T. Subjects and Methods: The coil consists of 8 transmit-receive shielded array elements, symmetrically distributed around the head region (Fig 1). The distance between the back shield and each array element as well as the dimension of each element were optimized in order to get the max B1 efficiency and minimum SAR value of the array using CST simulator [1]. PIN diodes in all elements allow for actively switching off of the head coil during reception by a receive-only coil. Additionally a transmit/receive switch was used for each channel to allow for switching between Tx and Rx mode using the head coil as a transceive coil alone. Results: Results of the EM simulations (Fig.2) show the maximum B1 efficiency of 0.4 [μT/sqrtW}]. The peak local SAR averaged over 10g cubes over the accepted power turned out to be 0.55 [1/kg] in CP+1 mode using CST human model [1]. any two channels at 297.2 MHz was lower than -20 dB. Fig.3 shows the measured B1 efficiency of the array using a sugar-water phantom after phase shimming (all 8 channels) with a maximum B1 efficiency of 0.46 [μT/sqrt{W}], whereas a maximum B1 efficiency of 0.34 [μT/sqrt{W}] was measured in an oil phantom and of 0.33 [μT/sqrt{W] in the human brain of a healthy volunteer respectively. Discussion/Conclusion: An 8-channel transceive head coil was constructed and evaluated on a 7T MRI system. The optimized coil array has been shown to produce high B1 efficiency and high SNR. This coil can be used both as a transceive coil alone (due to its high B1 efficiency and low SAR) and also as a transmit-only coil.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2013-10
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1007/s10334-013-0384-5
BibTex Citekey: YazdanbakhshRCHL2013
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 30th Annual Scientific Meeting ESMRMB 2013
Veranstaltungsort: Toulouse, France
Start-/Enddatum: -

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance Materials in Physics, Biology and Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 26 (Supplement 1) Artikelnummer: - Start- / Endseite: 345 - 346 Identifikator: -