日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  High Resolution Arterial Spin Labeling in the Human Brain at 9.4 T: Initial Results using FAIR

Bause, J., Shajan, G., Scheffler, K., & Pohmann, R. (2013). High Resolution Arterial Spin Labeling in the Human Brain at 9.4 T: Initial Results using FAIR. Magnetic Resonance Materials in Physics, Biology and Medicine, 26(Supplement 1), 257.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0001-4ECD-2 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0001-5177-E
資料種別: 会議抄録

ファイル

表示: ファイル

関連URL

表示:
非表示:
URL:
Link (全文テキスト(全般))
説明:
-
OA-Status:

作成者

表示:
非表示:
 作成者:
Bause, J1, 2, 著者           
Shajan, G1, 2, 著者           
Scheffler, K1, 2, 著者           
Pohmann, R1, 2, 著者           
所属:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
2Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

内容説明

表示:
非表示:
キーワード: -
 要旨: Purpose/Introduction: ASL at ultra-high field benefits from higher SNR and longer longitudinal relaxation times [1]. However, stronger B1 + and B0 field inhomogeneities are challenging for the preparation and readout of FAIR-ASL [2]. We were able to perform the first ASL experiments in the human brain at 9.4T using an optimized adiabatic inversion pulse in combination with a GRE-EPI readout [3]. Subjects and Methods: The protocol consisted of a FAIR preparation containing a time resampled FOCI (TR-FOCI) pulse followed by a 2D GREEPI readout with minimized temporal spacing between the acquisitions of the different slices. The TR-FOCI was optimized using a genetic algorithm described by Hurley et al. but with modified constraints to benefit from the capabilities of our scanner. A single subject (male, 28yo.) was measured on a Siemens Magnetom 9.4T scanner with a home-built 16ch transmit / 31ch receive array [4]. The required voltage of the TR-FOCI was estimated based on an actual flip angle (AFI) B1 + map. Additionally, the slice profile of the TR-FOCI was determined with an IR-GRE sequence. For the ASL experiment, forty label-control pairs (16 slices, 2x2x2mm3, no slice gap) were acquired at four different inversion times with flow crusher gradients. M0 was measured using the same EPI readout but with a longer TR. Image reconstruction and calculations were performed offline in Matlab (MathWorks, USA). Results: Fig. 1a shows the B1 + map scaled with the voltage of the inversion pulse. The measured slice profile at the same slice position is depicted in Fig. 1b. Fig. 2 displays the calculated perfusion weighted images for all TIs and every third slice. Note that the three most inferior slices were neglected due to the imperfect inversion slice profile. Discussion/Conclusion: This work shows that FAIR-ASL can be performed at 9.4T with 2mm isotropic resolution. An optimized adiabatic inversion pulse was used for the FAIR preparation in order to improve B1 + stability. In a future study, it may be beneficial to replace the non-selective tagging pulse with a spatially confined pulse to reduce the influence of the inferior transmit field variations [5]. For quantitative perfusion mapping with a single subtraction (QUIPSS), a further prolongation of the repetition time may be necessary since the SAR level was already close to the safety limit.

資料詳細

表示:
非表示:
言語:
 日付: 2013-10
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1007/s10334-013-0383-6
BibTex参照ID: BauseSSP2013
 学位: -

関連イベント

表示:
非表示:
イベント名: 30th Annual Scientific Meeting ESMRMB 2013
開催地: Toulouse, France
開始日・終了日: -

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance Materials in Physics, Biology and Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 26 (Supplement 1) 通巻号: - 開始・終了ページ: 257 識別子(ISBN, ISSN, DOIなど): -