日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Temperature uniformity in the CERN CLOUD chamber

Dias, A., Ehrhart, S., Vogel, A., Williamson, C., Almeida, J., Kirkby, J., Mathot, S., Mumford, S., & Onnela, A. (2017). Temperature uniformity in the CERN CLOUD chamber. Atmospheric Measurement Techniques, 10(12), 5075-5088. doi:10.5194/amt-10-5075-2017.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0001-5642-4 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0001-5643-3
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Dias, Antonio1, 著者
Ehrhart, S.2, 著者           
Vogel, Alexander1, 著者
Williamson, Christina1, 著者
Almeida, Joao1, 著者
Kirkby, Jasper1, 著者
Mathot, Serge1, 著者
Mumford, Samuel1, 著者
Onnela, Antti1, 著者
所属:
1external, ou_persistent22              
2Atmospheric Chemistry, Max Planck Institute for Chemistry, Max Planck Society, ou_1826285              

内容説明

表示:
非表示:
キーワード: -
 要旨: The CLOUD (Cosmics Leaving OUtdoor Droplets) experiment at CERN (European Council for Nuclear Research) investigates the nucleation and growth of aerosol particles under atmospheric conditions and their activation into cloud droplets. A key feature of the CLOUD experiment is precise control of the experimental parameters. Temperature uniformity and stability in the chamber are important since many of the processes under study are sensitive to temperature and also to contaminants that can be released from the stainless steel walls by upward temperature fluctuations. The air enclosed within the 26 m 3 CLOUD chamber is equipped with several arrays (“strings”) of high precision, fast-response thermometers to measure its temperature. Here we present a study of the air temperature uniformity inside the CLOUD chamber under various experimental conditions. Measurements were performed under calibration conditions and run conditions, which are distinguished by the flow rate of fresh air and trace gases entering the chamber at 20 and up to 210 L min − 1 , respectively. During steady-state calibration runs between − 70 and + 20 ◦ C, the air temperature uniformity is better than ± 0.06 ◦ C in the radial direction and ± 0.1 ◦ C in the vertical direction. Larger non-uniformities are present during experimental runs, depending on the temperature control of the make-up air and trace gases (since some trace gases require elevated temperatures until injection into the cham- ber). The temperature stability is ± 0.04 ◦ C over periods of several hours during either calibration or steady-state run conditions. During rapid adiabatic expansions to activate cloud droplets and ice particles, the chamber walls are up to 10 ◦ C warmer than the enclosed air. This results in temperature differences of ± 1.5 ◦ C in the vertical direction and ± 1 ◦ C in the horizontal direction, while the air returns to its equilibrium temperature with a time constant of about 200 s.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2017
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): ISI: 000418683900001
DOI: 10.5194/amt-10-5075-2017
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Atmospheric Measurement Techniques
  省略形 : AMT
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Göttingen : European Geosciences Union, Copernicus
ページ: - 巻号: 10 (12) 通巻号: - 開始・終了ページ: 5075 - 5088 識別子(ISBN, ISSN, DOIなど): ISSN: 1867-1381
CoNE: https://pure.mpg.de/cone/journals/resource/1867-1381