Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Are hydroethidine-based probes reliable for ROS detection?

Xiao, Y., & Meierhofer, D. (2019). Are hydroethidine-based probes reliable for ROS detection? ANTIOXIDANTS & REDOX SIGNALING, 31(4), 359-367. doi:10.1089/ars.2018.7535.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
Xiao2019.pdf (Verlagsversion), 3MB
Name:
Xiao2019.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
© Yi Xiao and David Meierhofer 2018

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Xiao, Yi1, Autor           
Meierhofer, David1, Autor           
Affiliations:
1Mass Spectrometry (Head: David Meierhofer), Scientific Service (Head: Christoph Krukenkamp), Max Planck Institute for Molecular Genetics, Max Planck Society, ou_1479669              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Reactive oxygen species, ROS; superoxide, O· 2 −; mass spectrometry; multiple reaction monitoring, MRM; hydroethidine, HE; mito-hydroethidine, mitoSOX red or mito- HE; hydropropidine, HPr+
 Zusammenfassung: Detection and quantification of the highly reactive and short lived superoxide (O·2-) can be challenging. Here, we present a new mass spectrometry (MS)-based method to detect and quantify O·2- using three fluorogenic hydroethidine probes: HE, mito-HE, and HPr+, which measure cytosolic, mitochondrial and extracellular O·2-, respectively. The probes and their oxidation products were simultaneously quantified by applying multiple reaction monitoring (MRM) with mass spectrometry that allowed the specific measurement of ROS distribution within the cell. The advantage of this LC-MS/MS method is that co-eluting compounds can be precisely distinguished using specific precursor and fragment masses. This method overcomes limitations from spectral overlap of O·2- specific and non-specific products in fluorescence spectra or the low specificity associated with chromatography-based approaches. However, our experiments showed that these hydroethidine probes can be prone to autoxidation during incubation at 37 °C in Hank's solution. Cell treatments with strong oxidants did not significantly increase levels of the O·2- radical. Thus, subtle changes in ROS levels in cell culture experiments might not be quantifiable. Our findings raise the question of whether hydroethidine-based probes can be used for the reliable detection of O·2- radicals in cell culture.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2018-05-222019-06-242019-08-01
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1089/ars.2018.7535
PMID: 9790367
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: ANTIOXIDANTS & REDOX SIGNALING
  Andere : Antioxid. Redox Signal.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Larchmont, NY : Mary Ann Liebert, Inc.
Seiten: 9 Band / Heft: 31 (4) Artikelnummer: - Start- / Endseite: 359 - 367 Identifikator: ISSN: 1523-0864
CoNE: https://pure.mpg.de/cone/journals/resource/110978984449337