English
 
User Manual Privacy Policy Disclaimer Contact us
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Hydrogen peroxide sensor based on electrodeposited Prussian blue film

Lu, S.-Y., Chen, Y., Fang, X., & Feng, X. (2017). Hydrogen peroxide sensor based on electrodeposited Prussian blue film. Journal of Applied Electrochemistry, 47(11), 1261-1271. doi:10.1007/s10800-017-1113-y.

Item is

Basic

show hide
Item Permalink: http://hdl.handle.net/21.11116/0000-0001-6413-9 Version Permalink: http://hdl.handle.net/21.11116/0000-0001-6E6E-A
Genre: Journal Article

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Lu, Si-Yuan1, 2, Author              
Chen, Yihao1, 2, Author              
Fang, Xufei1, 2, 3, Author              
Feng, Xue1, 2, Author              
Affiliations:
1AML, School of Aerospace Engineering, Tsinghua University, Beijing, China, persistent22              
2Center for Advanced Mechanics and Materials, Tsinghua University, Beijing, China, persistent22              
3Nanotribology, Structure and Nano-/ Micromechanics of Materials, Max-Planck-Institut für Eisenforschung GmbH, Max Planck Society, ou_1863402              

Content

show
hide
Free keywords: SCREEN-PRINTED ELECTRODES; AMPEROMETRIC BIOSENSOR; GLUCOSE BIOSENSOR; H2O2; TRANSDUCER; ARRAYS; ENZYME; PROBESElectrochemistry; Hydrogen peroxide; Prussian blue; Electrochemical deposition; Electrochemically modified sensor;
 Abstract: Prussian blue (PB) films have been widely used for blood glucose monitoring. Here, we present the strategy to improve the performance and sensitivity of PB film for hydrogen peroxide (H2O2) monitoring by using modified gold electrode for hydrogen peroxide monitoring. The microstructure of the studied electrodes was characterized using scanning electron microscopy and atomic force microscopy. The electrochemical properties of experimental electrodes were obtained via cyclic voltammograms and chronoamperometry methods. The results show that the thickness of deposited PB film is increased with the deposition time. The PB-modified electrode exhibits the widest linear range and best operational stability after being electrochemically deposited for 240 s. The highest sensitivity for experimental electrodes is obtained on samples deposited for 40 s (341 mA cm(-2) M-1), indicating that a thinner PB film with certain critical thickness can accelerate the exchanging rate of K+ between PB lattice and the tested solution.

Details

show
hide
Language(s): eng - English
 Dates: 2017-11-01
 Publication Status: Published in print
 Pages: 11
 Publishing info: -
 Table of Contents: -
 Rev. Method: Peer
 Identifiers: ISI: 000412932300007
DOI: 10.1007/s10800-017-1113-y
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Applied Electrochemistry
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: London : Chapman and Hall.
Pages: - Volume / Issue: 47 (11) Sequence Number: - Start / End Page: 1261 - 1271 Identifier: ISSN: 0021-891X
CoNE: /journals/resource/954925410814