日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Hydrogen peroxide sensor based on electrodeposited Prussian blue film

Lu, S.-Y., Chen, Y., Fang, X., & Feng, X. (2017). Hydrogen peroxide sensor based on electrodeposited Prussian blue film. Journal of Applied Electrochemistry, 47(11), 1261-1271. doi:10.1007/s10800-017-1113-y.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0001-6413-9 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0001-6E6E-A
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Lu, Si-Yuan1, 2, 著者           
Chen, Yihao1, 2, 著者           
Fang, Xufei1, 2, 3, 著者           
Feng, Xue1, 2, 著者           
所属:
1AML, School of Aerospace Engineering, Tsinghua University, Beijing, China, persistent22              
2Center for Advanced Mechanics and Materials, Tsinghua University, Beijing, China, persistent22              
3Nanotribology, Structure and Nano-/ Micromechanics of Materials, Max-Planck-Institut für Eisenforschung GmbH, Max Planck Society, ou_1863402              

内容説明

表示:
非表示:
キーワード: SCREEN-PRINTED ELECTRODES; AMPEROMETRIC BIOSENSOR; GLUCOSE BIOSENSOR; H2O2; TRANSDUCER; ARRAYS; ENZYME; PROBESElectrochemistry; Hydrogen peroxide; Prussian blue; Electrochemical deposition; Electrochemically modified sensor;
 要旨: Prussian blue (PB) films have been widely used for blood glucose monitoring. Here, we present the strategy to improve the performance and sensitivity of PB film for hydrogen peroxide (H2O2) monitoring by using modified gold electrode for hydrogen peroxide monitoring. The microstructure of the studied electrodes was characterized using scanning electron microscopy and atomic force microscopy. The electrochemical properties of experimental electrodes were obtained via cyclic voltammograms and chronoamperometry methods. The results show that the thickness of deposited PB film is increased with the deposition time. The PB-modified electrode exhibits the widest linear range and best operational stability after being electrochemically deposited for 240 s. The highest sensitivity for experimental electrodes is obtained on samples deposited for 40 s (341 mA cm(-2) M-1), indicating that a thinner PB film with certain critical thickness can accelerate the exchanging rate of K+ between PB lattice and the tested solution.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2017-11-01
 出版の状態: 出版
 ページ: 11
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): ISI: 000412932300007
DOI: 10.1007/s10800-017-1113-y
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Journal of Applied Electrochemistry
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: London : Chapman and Hall.
ページ: - 巻号: 47 (11) 通巻号: - 開始・終了ページ: 1261 - 1271 識別子(ISBN, ISSN, DOIなど): ISSN: 0021-891X
CoNE: https://pure.mpg.de/cone/journals/resource/954925410814