English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Comparison of B0 versus B0 and B1 field inhomogeneity correction for glycosaminoglycan chemical exchange saturation transfer imaging

Müller-Lutz, A., Lijmani, A., Stabinska, J., Zaiss, M., Boos, J., & Wittsack, H.-J. (2018). Comparison of B0 versus B0 and B1 field inhomogeneity correction for glycosaminoglycan chemical exchange saturation transfer imaging. Magnetic Resonance Materials in Physics, Biology and Medicine, 31(5), 645-651. doi:10.1007/s10334-018-0689-5.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Müller-Lutz, A, Author
Lijmani, A, Author
Stabinska, J, Author
Zaiss, M1, 2, Author           
Boos, J, Author
Wittsack, H-J, Author
Affiliations:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
2Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Content

show
hide
Free keywords: -
 Abstract: Purpose The study compares glycosaminoglycan chemical exchange saturation transfer (gagCEST) imaging of intervertebral discs corrected for solely B0 inhomogeneities or both B0 and B1 inhomogeneities. Methods Lumbar intervertebral discs of 20 volunteers were examined with T2-weighted and gagCEST imaging. Field inhomogeneity correction was performed with B0 correction only and with correction of both B0 and B1. GagCEST effects measured by the asymmetric magnetization transfer ratio (MTRasym) and signal-to-noise ratio (SNR) were compared between both methods. Results Significant higher MTRasym and SNR values were obtained in the nucleus pulposus using B0 and B1 correction compared with B0-corrected gagCEST. The GagCEST effect was significantly different in the nucleus pulposus compared with the annulus fibrosus for both methods. Conclusion The B0 and B1 field inhomogeneity correction method leads to an improved quality of gagCEST imaging in IVDs compared with only B0 correction.

Details

show
hide
Language(s):
 Dates: 2018-052018-10
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1007/s10334-018-0689-5
BibTex Citekey: MullerLutzLSZBW2018
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance Materials in Physics, Biology and Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Amsterdam : No longer published by Elsevier
Pages: - Volume / Issue: 31 (5) Sequence Number: - Start / End Page: 645 - 651 Identifier: ISSN: 0968-5243
CoNE: https://pure.mpg.de/cone/journals/resource/954926245532