Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Comparison of B0 versus B0 and B1 field inhomogeneity correction for glycosaminoglycan chemical exchange saturation transfer imaging

Müller-Lutz, A., Lijmani, A., Stabinska, J., Zaiss, M., Boos, J., & Wittsack, H.-J. (2018). Comparison of B0 versus B0 and B1 field inhomogeneity correction for glycosaminoglycan chemical exchange saturation transfer imaging. Magnetic Resonance Materials in Physics, Biology and Medicine, 31(5), 645-651. doi:10.1007/s10334-018-0689-5.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Müller-Lutz, A, Autor
Lijmani, A, Autor
Stabinska, J, Autor
Zaiss, M1, 2, Autor           
Boos, J, Autor
Wittsack, H-J, Autor
Affiliations:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
2Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Purpose The study compares glycosaminoglycan chemical exchange saturation transfer (gagCEST) imaging of intervertebral discs corrected for solely B0 inhomogeneities or both B0 and B1 inhomogeneities. Methods Lumbar intervertebral discs of 20 volunteers were examined with T2-weighted and gagCEST imaging. Field inhomogeneity correction was performed with B0 correction only and with correction of both B0 and B1. GagCEST effects measured by the asymmetric magnetization transfer ratio (MTRasym) and signal-to-noise ratio (SNR) were compared between both methods. Results Significant higher MTRasym and SNR values were obtained in the nucleus pulposus using B0 and B1 correction compared with B0-corrected gagCEST. The GagCEST effect was significantly different in the nucleus pulposus compared with the annulus fibrosus for both methods. Conclusion The B0 and B1 field inhomogeneity correction method leads to an improved quality of gagCEST imaging in IVDs compared with only B0 correction.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2018-052018-10
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1007/s10334-018-0689-5
BibTex Citekey: MullerLutzLSZBW2018
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance Materials in Physics, Biology and Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Amsterdam : No longer published by Elsevier
Seiten: - Band / Heft: 31 (5) Artikelnummer: - Start- / Endseite: 645 - 651 Identifikator: ISSN: 0968-5243
CoNE: https://pure.mpg.de/cone/journals/resource/954926245532