  Ex vivo continuous Overhauser nuclear dynamic polarization in a SQUID-based ultralow-field magnetic resonance imaging system

Fehling, P., Bernard, R., Pohmann, R., Rudolph, M., Koelle, D., Kleiner, R., et al. (2018). Ex vivo continuous Overhauser nuclear dynamic polarization in a SQUID-based ultralow-field magnetic resonance imaging system. In 82. Jahrestagung der Deutschen Physikalischen Gesellschaft und DPG-Frühjahrstagung (pp. 96).

Item is

Basisdaten

einblenden: ausblenden:
Genre: Meeting Abstract

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
Link (Zusammenfassung)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Fehling, P1, 2, Autor           
Bernard, R1, 2, Autor           
Pohmann, R1, 2, Autor           
Rudolph, M1, 2, Autor           
Koelle, D, Autor
Kleiner, R, Autor
Scheffler, K1, 2, Autor           
Buckenmaier, K1, 2, Autor           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Overhauser Dynamic Nuclear Polarization (ODNP) is a hyperpolarization method for magnetic resonance measurements. The polarization of free radicals is transferred to 1H using HF pulses, thus enhancing the 1H signal. Only at UltraLow Fields (ULF) below 10 mT the corresponding HF pulse frequencies are low enough to penetrate large sample volumes, making continuous in vivo hyperpolarization possible. Since conventional Faraday coils are not sensitive enough at ULF, a SQUID-based detector is employed as the centerpiece of the ULF-MRI Scanner. With a superconducting second order gradiometric pickup coil the SQUID enables measurements with a sensitivity below 1 fT/√Hz. First proof-of-principle ex vivo images using ODNP enhanced, SQUID based ULF-MRI have been acquired successfully. This is an important step in the direction of a combined ULF MRI and magnetoencephalography system.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2018-03
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: BibTex Citekey: FehlingBPRKKSB2018
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: 82. Jahrestagung der Deutschen Physikalischen Gesellschaft und DPG-Frühjahrstagung
Veranstaltungsort: Berlin, Germany
Start-/Enddatum: 2018-03-11 - 2018-03-16

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: 82. Jahrestagung der Deutschen Physikalischen Gesellschaft und DPG-Frühjahrstagung
Genre der Quelle: Konferenzband
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: - Artikelnummer: TT 49.4 Start- / Endseite: 96 Identifikator: -