Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Microwave injection for the ALPHATRAP experiment and developments of the multi-reflection time-of-flight technique of the ISOLTRAP experiment

Steinsberger, T. (2018). Microwave injection for the ALPHATRAP experiment and developments of the multi-reflection time-of-flight technique of the ISOLTRAP experiment. Master Thesis, Ruprecht-Karls-Universität, Heidelberg.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Hochschulschrift

Dateien

einblenden: Dateien
ausblenden: Dateien
:
master_thesis_Timo_Steinsberger.pdf (Verlagsversion), 35MB
Name:
master_thesis_Timo_Steinsberger.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Steinsberger, Timo1, Autor           
Affiliations:
1Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society, ou_904548              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 MPINP: Präzisionsexperimente - Abteilung Blaum
 Zusammenfassung: This thesis presents work done at the ALPHATRAP g-factor experiment at the MPIK in Heidelberg and at the mass spectrometry experiment ISOLTRAP at ISOLDE/CERN. At ALPHATRAP a system for microwave transmission from the room temperature environment to the cryogenic trap tower was designed. Microwave horns were used for contact free power transfer in a rst step to a 77K temperature shield and in a second step to the trap tower cooled to 4:2 K. Additional devices for the alignment of a laser beam with the microwaves and a mode lter were designed. At ISOLTRAP, studies for multi-refl ection time-of- flight mass measurements (MR-ToF MS) were performed. A distortion of the peaks in the time-of- ight spectrum due to the radiofrequency eld in the RFQ used for beam preparation was investigated and reduced. In order to improve the ion optics, a new Einzel lens was designed and a new quadrupole bender was commissioned. The stability of mass measurements using the ISOLTRAP MR-ToF MS with ions from an o-line reference ion source were investigated. For measurements with a total recording time of more than one minute, a systematic error on the order of 100 keV was determined. It was reduced for shorter measurement cycles, where the uncertainty due to low statistics dominates.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2018
 Publikationsstatus: Angenommen
 Seiten: VI, 93 S. : Ill., graph. Darst.
 Ort, Verlag, Ausgabe: Heidelberg : Ruprecht-Karls-Universität
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: -
 Art des Abschluß: Master

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle

einblenden: