  Detection and characterization of dimethylethanolamine‐based corrosion inhibitors at steel surfaces. I. The use of XPS and ToF‐SIMS

Brundle, C., Grunze, M., Mäder, U., & Blank, N. (1996). Detection and characterization of dimethylethanolamine‐based corrosion inhibitors at steel surfaces. I. The use of XPS and ToF‐SIMS. Surface and Interface Analysis, 24(9), 549-563. doi:10.1002/(SICI)1096-9918(19960916)24:9%3C549:AID-SIA164%3E3.0.CO;2-Z.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel
Alternativer Titel : Detection and characterization of dimethylethanolamine-based corrosion inhibitors at steel surfaces; (I) the use of XPS and ToF-SIMS

Dateien

einblenden: Dateien
ausblenden: Dateien
:
SurfInterfaceAnal_24_1996_549.pdf (beliebiger Volltext), 2MB
 
Datei-Permalink:
-
Name:
SurfInterfaceAnal_24_1996_549.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (Max Planck Institute for Medical Research, MHMF; )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Brundle, C.R., Autor
Grunze, M.1, Autor           
Mäder, U., Autor
Blank, N., Autor
Affiliations:
1Cellular Biophysics, Max Planck Institute for Medical Research, Max Planck Society, ou_2364731              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Formulations based on dilute aqueous solutions ofN,N′‐dimethylethanolamine (DMEA) are used to protect reinforcement steel bars (‘rebar’) in concrete from corrosion. In a series of papers we will discuss the mechanism of corrosion inhibition and migration of DMEA through a cement matrix. Here we investigate the usefulness of XPS and SIMS in detecting the presence of DMEA at Au and steel surfaces, and in providing quantitative and chemical state information after various treatment schemes. We conclude that XPS can provide semi‐quantitative information down to a coverage level which depends on the amount of other contaminant species present. Some useful information on chemical states is provided from exact core‐level binding energies. Secondary ion mass spectrometry in the high mass resolution static mode, using time‐of‐flight, provides direct evidence for the presence of specific molecular or fragment components of DMEA, which XPS cannot identify. SIMS can, therefore, be used as a ‘tracer’ for the presence of DMEA, even in the presence of strong contamination. Both methods reveal differences in the surface chemistry after differing surface treatments.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 1995-11-141996-05-051996-09-01
 Publikationsstatus: Erschienen
 Seiten: 15
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Surface and Interface Analysis
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York, NY : John Wiley & Sons
Seiten: - Band / Heft: 24 (9) Artikelnummer: - Start- / Endseite: 549 - 563 Identifikator: ISSN: 0142-2421
CoNE: https://pure.mpg.de/cone/journals/resource/954925471358