Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Corrigendum to “Time and potential resolved dissolution analysis of rhodium using a microelectrochemical flow cell coupled to an ICP-MS” [Journal of Electroanalytical Chemistry 677–680 (2012) 50–55] (S1572665712001865) (10.1016/j.jelechem.2012.05.006))

Klemm, S. O., Karschin, A., Mechler, A. K., Topalov, A. A., Katsounaros, I., & Mayrhofer, K. J. J. (2013). Corrigendum to “Time and potential resolved dissolution analysis of rhodium using a microelectrochemical flow cell coupled to an ICP-MS” [Journal of Electroanalytical Chemistry 677–680 (2012) 50–55] (S1572665712001865) (10.1016/j.jelechem.2012.05.006)). Journal of Electroanalytical Chemistry, 693, 127. doi:10.1016/j.jelechem.2013.01.012.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Klemm, Sebasian Oliver1, Autor           
Karschin, Arndt1, 2, Autor           
Mechler, Anna Katharina1, Autor           
Topalov, Angel Angelov1, Autor           
Katsounaros, Ioannis1, Autor           
Mayrhofer, Karl Johann Jakob1, Autor           
Affiliations:
1Electrocatalysis, Interface Chemistry and Surface Engineering, Max-Planck-Institut für Eisenforschung GmbH, Max Planck Society, ou_1863354              
2Insitut für Anorganische Chemie und Strukturchemie, Lehrstuhl I: Bioanorganische Chemie und Katalyse, Heinrich Heine Universität Düsseldorf, Universitätsstraße 1, Düsseldorf, Germany, persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: The authors regret that in the article an error during area normalization of the dissolution during potential step experiments occurred. All measurements and conclusions concerning potentiodynamic protocols are however unaffected by the errors described above and therefore still valid in the original form. The following corrections need to be considered: - The steady state dissolution rate calculated on page 54, end of 3rd paragraph, equals 3.9 pg s−1 cm−2, not “fg s−1 cm−2”. Therefore, in the abstract the steady-state dissolution “ranges around a few picograms per second and square centimeter” instead of femtograms.- The values in Fig. 6 have been corrected and are shown below:Taking the revised values, it can no longer be stated that potential steps yield lower dissolution rates than sweeps in identical potential windows. The dissolution integral observed during the step between 1 and 0 VSHE (7.7 ng cm−2) is in fact higher than the fast cycling experiments from Fig. 4 (3.87 ng cm−2 cycle−1). The initial assumption that both measurement protocols are directly comparable therefore appears unlikely. This originates most likely from the long hold periods at oxidizing and reducing potentials in the potentiostatic series, which are absent in the successive cycling used for potentiodynamic measurements. © 2013 Elsevier B.V.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2013-03-01
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1016/j.jelechem.2013.01.012
BibTex Citekey: Klemm2013127
ISSN: 15726657
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of Electroanalytical Chemistry
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Amsterdam : Elsevier
Seiten: - Band / Heft: 693 Artikelnummer: - Start- / Endseite: 127 Identifikator: ISSN: 0022-0728
CoNE: https://pure.mpg.de/cone/journals/resource/954928572675