Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Optimization of pulse train presaturation for CEST imaging in clinical scanners

Schmitt, B., Zaiss, M., Zhou, J., & bachert, P. (2011). Optimization of pulse train presaturation for CEST imaging in clinical scanners. Magnetic Resonance in Medicine, 65(6), 1620-1629. doi:10.1002/mrm.22750.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Schmitt, B, Autor
Zaiss, M1, Autor           
Zhou, J, Autor
bachert, P, Autor
Affiliations:
1Department of Medical Physics in Radiology, Deutsches Krebsforschungszentrum (DKFZ, German Cancer Research Center), Heidelberg, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Chemical exchange saturation transfer (CEST) imaging depends on the performance of radiofrequency saturation during the experiment. Scanner specifications, in particular limited pulse width and duty‐cycle, and specific absorption rate guidelines restrict the full exploitation of CEST effects in clinical MR systems. The purpose of this study was to optimize techniques for effective pulse train presaturation for CEST imaging in a whole‐body MR scanner. Theoretical analysis and simulations of the spectral properties of radiofrequency pulse trains demonstrated the significance of pulse width τP and interpulse delay τD for effective and selective labeling of a chemically exchanging proton pool. CEST experiments with model solutions, e.g., creatine dissolved in water, showed best performance of pulse trains with τP = τD = 100 msec, regarding minimum direct water saturation in z‐spectra and distinct magnetization transfer ratio asymmetry that can be determined quantitatively. Saturation efficiency of trains of Gaussian‐shaped radiofrequency pulses using this timing was evaluated in MR imagers with field strengths of 1.5, 3, and 7 T. The proposed saturation pulse train does not require hardware modifications, offers low specific absorption rate, and can be used in a standard clinical setup.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2011-06
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1002/mrm.22750
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York : Wiley-Liss
Seiten: - Band / Heft: 65 (6) Artikelnummer: - Start- / Endseite: 1620 - 1629 Identifikator: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149