日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  CEST imaging at 9.4 T using adjusted adiabatic spin‐lock pulses for on‐ and off‐resonant T1⍴‐dominated Z‐spectrum acquisition

Herz, K., Gandhi, C., Schuppert, M., Deshmane, A., Scheffler, K., & Zaiss, M. (2018). CEST imaging at 9.4 T using adjusted adiabatic spin‐lock pulses for on‐ and off‐resonant T1⍴‐dominated Z‐spectrum acquisition. Magnetic Resonance in Medicine, Epub ahead. doi:10.1002/mrm.27380.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0002-1132-2 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0002-1133-1
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Herz, K1, 2, 著者           
Gandhi, C1, 2, 著者           
Schuppert, M1, 2, 著者           
Deshmane, A1, 2, 著者           
Scheffler, K1, 2, 著者           
Zaiss, M1, 2, 著者           
所属:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

内容説明

表示:
非表示:
キーワード: -
 要旨: Purpose The CEST experiment, with its correlation to rare proton species that are in exchange with the water pool, is very similar to the off‐resonant water spin‐lock (SL) experiment. In particular, low‐power SL Z‐spectrum acquisition allows insight into T1ρ and exchange effects with decreased direct water saturation. Because the available SL methods either require high B1 power or are instable in the presence of strong B1 and B0 inhomogeneity present at ultra‐high fields, the goal of this study was to find a robust adiabatic SL pulse for on‐ and off‐resonant application in the human brain at 9.4 T. Methods A series of Bloch simulations were used to find optimal pulse shape parameters of an adjusted hyperbolic secant pulse applicable in the low power regime typically used for exchange‐weighted SL experiments. The optimized pulse was implemented and tested in phantom and in vivo experiments on a 9.4 T human scanner for on‐ and off‐resonant T1ρ‐ and Z‐spectrum measurements. Results The simulation yielded a feasible pulse shape, which yielded robust images, less sensitivity to B1 and B0 inhomogeneity compared with previous SL approaches and less direct water saturation, as well as a higher chemical exchange weighting compared with conventional CEST approaches. Conclusion By adapting a pulse shape for low‐power SL experiments, we were able to acquire robust on‐ and off‐resonant adiabatic SL prepared images in vivo at 9.4 T. This development leads directly to SL Z‐spectrum acquisition, beneficial for chemical‐exchange‐weighted MRI.

資料詳細

表示:
非表示:
言語:
 日付: 2018-09
 出版の状態: オンラインで出版済み
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1002/mrm.27380
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance in Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: New York : Wiley-Liss
ページ: - 巻号: Epub ahead 通巻号: - 開始・終了ページ: - 識別子(ISBN, ISSN, DOIなど): ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149