Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Semisynthetic sensor proteins enable metabolic assays at the point of care

Yu, Q., Xue, L., Hiblot, J., Griss, R., Fabritz, S., Roux, C., et al. (2018). Semisynthetic sensor proteins enable metabolic assays at the point of care. Science, 361(6407), 1122-1126. doi:10.1126/science.aat7992.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
Science_361_2018_1122.pdf (beliebiger Volltext), 706KB
 
Datei-Permalink:
-
Name:
Science_361_2018_1122.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (Max Planck Institute for Medical Research, MHMF; )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
http://science.sciencemag.org/content/361/6407/1122/tab-pdf (beliebiger Volltext)
Beschreibung:
-
OA-Status:
externe Referenz:
https://doi.org/10.1126/science.aat7992 (beliebiger Volltext)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Yu, Qiuliyang1, Autor           
Xue, Lin1, Autor           
Hiblot, Julien1, Autor           
Griss , Rudolf, Autor
Fabritz, Sebastian1, Autor           
Roux, Clothilde, Autor
Binz, Pierre-Alain, Autor
Haas, Dorothea, Autor
Okun, Jürgen G., Autor
Johnsson, Kai1, Autor           
Affiliations:
1Chemical Biology, Max Planck Institute for Medical Research, Max Planck Society, ou_2364732              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Monitoring metabolites at the point of care could improve the diagnosis and management of numerous diseases. Yet for most metabolites, such assays are not available. We introduce semisynthetic, light-emitting sensor proteins for use in paper-based metabolic assays. The metabolite is oxidized by nicotinamide adenine dinucleotide phosphate, and the sensor changes color in the presence of the reduced cofactor, enabling metabolite quantification with the use of a digital camera. The approach makes any metabolite that can be oxidized by the cofactor a candidate for quantitative point-of-care assays, as shown for phenylalanine, glucose, and glutamate. Phenylalanine blood levels of phenylketonuria patients were analyzed at the point of care within minutes with only 0.5 microliters of blood. Results were within 15% of those obtained with standard testing methods.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2018-04-052018-08-092018-09-142018-09-14
 Publikationsstatus: Erschienen
 Seiten: 5
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1126/science.aat7992
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Science
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Washington, D.C. : American Association for the Advancement of Science
Seiten: - Band / Heft: 361 (6407) Artikelnummer: - Start- / Endseite: 1122 - 1126 Identifikator: ISSN: 0036-8075
CoNE: https://pure.mpg.de/cone/journals/resource/991042748276600_1