English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Variable flip angle T1 mapping in the human brain with reduced t2 sensitivity using fast radiofrequency‐spoiled gradient echo imaging

Heule, R., Bieri, O., & Ganter, C. (2016). Variable flip angle T1 mapping in the human brain with reduced t2 sensitivity using fast radiofrequency‐spoiled gradient echo imaging. Magnetic Resonance in Medicine, 75(4), 1413-1422. doi:10.1002/mrm.25668.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Heule, R1, Author           
Bieri, O, Author
Ganter, C, Author
Affiliations:
1University of Basel Hospital, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: Purpose
Variable flip angle (VFA) T1 quantification using three‐dimensional (3D) radiofrequency (RF) spoiled gradient echo imaging offers the acquisition of whole‐brain T1 maps in clinically acceptable times. However, conventional VFA T1 relaxometry is biased by incomplete spoiling (i.e., residual T2 dependency). A new postprocessing approach is proposed to overcome this T2‐related bias.
Methods
T1 is quantified from the signal ratio of two spoiled gradient echo (SPGR) images acquired at different flip angles using an analytical solution for the RF‐spoiled steady‐state signal in combination with a global T2 guess. T1 accuracy is evaluated from simulations and in vivo 3D SPGR imaging of the human brain at 3 Tesla.
Results
The simulations demonstrated that the sensitivity of VFA T1 mapping to T2 can considerably be reduced using a global T2 guess. The method proved to deliver reliable and accurate T1 values in vivo for white and gray matter in good agreement with inversion recovery reference measurements.
Conclusion
Based on a global T2 estimate, the accuracy of VFA T1 relaxometry in the human brain can substantially be improved compared with conventional approaches which rely on the generally wrong assumption of ideal spoiling.

Details

show
hide
Language(s):
 Dates: 2016-04
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.25668
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Wiley-Liss
Pages: - Volume / Issue: 75 (4) Sequence Number: - Start / End Page: 1413 - 1422 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149