  Setup of a vibration-suppressed cryogenic system for a RF ion trap with minimum micromotion

Spieß, L. J. (2018). Setup of a vibration-suppressed cryogenic system for a RF ion trap with minimum micromotion. Master Thesis, Ruprecht-Karls-Universität, Heidelberg.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Hochschulschrift

Dateien

einblenden: Dateien
ausblenden: Dateien
:
MA_Spiess.pdf (beliebiger Volltext), 19MB
Name:
MA_Spiess.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Spieß, Lukas Josef1, Autor           
Affiliations:
1Division Prof. Dr. Thomas Pfeifer, MPI for Nuclear Physics, Max Planck Society, ou_2025284              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Recent advancements allow for sympathetic cooling of highly charged ions
(HCI) to mK temperatures in a cryogenic linear Paul trap. This makes high
precision spectroscopy of HCI possible, paving the way to the search for new
physics and novel optical clocks. For this, a highly stable and well-understood
Paul trap is required. In particular, excess micromotion needs to be characterized
and reduced, since it can limit the lowest achievable ion temperature
and therefore spectroscopic precision. Within this thesis, a new cryogenic
supply system was partly assembled, which allows for vibrational decoupling
of the trap, increasing storage stability. The first cool down test achieved a
temperature of 4:23K in the trap environment, which is sufficiently low for
superconductive operation of the intended RF-resonator made from niobium.
Additionally, a photon-correlation technique was used on the existing cryogenic
linear Paul trap using 9Be+ ions for determination of the trap frequency by
measuring the phase shift between the driven ions motion and the driving field.
From the trap frequency the magnification of the imaging system is deduced.
The same photon-correlation technique is used to measure excess micromotion
and to demonstrate its reduction by a factor of 100 compared to a previous
measurement by using new electronics.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2018
 Publikationsstatus: Angenommen
 Seiten: 86 S. : Ill., graph. Darst.
 Ort, Verlag, Ausgabe: Heidelberg : Ruprecht-Karls-Universität