Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Improved homogeneity of the transmit field by simultaneous transmission with phased array and volume coil

Avdievich, N., Oh, S., Hetherington, H., & Collins, C. (2010). Improved homogeneity of the transmit field by simultaneous transmission with phased array and volume coil. Journal of Magnetic Resonance Imaging, 32(2), 476-481. doi:10.1002/jmri.22257.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Avdievich, N1, Autor           
Oh, S, Autor
Hetherington, HP, Autor
Collins, CM, Autor
Affiliations:
1Yale University, New Haven, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung:
Purpose:

To improve the homogeneity of transmit volume coils at high magnetic fields (≥4 T). Due to radiofrequency (RF) field/tissue interactions at high fields, 4 T to 8 T, the transmit profile from head‐sized volume coils shows a distinctive pattern with relatively strong RF magnetic field B1 in the center of the brain.
Materials and Methods:

In contrast to conventional volume coils at high field strengths, surface coil phased arrays can provide increased RF field strength peripherally. In theory, simultaneous transmission from these two devices could produce a more homogeneous transmission field. To minimize interactions between the phased array and the volume coil, counter rotating current (CRC) surface coils consisting of two parallel rings carrying opposite currents were used for the phased array.
Results:

Numerical simulations and experimental data demonstrate that substantial improvements in transmit field homogeneity can be obtained.
Conclusion:

We have demonstrated the feasibility of using simultaneous transmission with human head‐sized volume coils and CRC phased arrays to improve homogeneity of the transmit RF B1 field for high‐field MRI systems.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2010-08
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1002/jmri.22257
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of Magnetic Resonance Imaging
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Chicago, IL : Society for Magnetic Resonance Imaging
Seiten: - Band / Heft: 32 (2) Artikelnummer: - Start- / Endseite: 476 - 481 Identifikator: ISSN: 1053-1807
CoNE: https://pure.mpg.de/cone/journals/resource/954925594512