  RF shimming for spectroscopic localization in the human brain at 7 T

Hetherington, H., Avdievich, N., Kuznetsov, A., & Pan, J. (2010). RF shimming for spectroscopic localization in the human brain at 7 T. Magnetic Resonance in Medicine, 63(1), 9-19. doi:10.1002/mrm.22182.

Item is

Basic

show hide
Genre: Journal Article

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Hetherington, HP, Author
Avdievich, N1, Author           
Kuznetsov, AM, Author
Pan, JW, Author
Affiliations:
1Yale University School of Medicine, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: Spectroscopic imaging of the human head at short echo times (≤15 ms) typically requires suppression of signals from extracerebral tissues. However, at 7 T, decreasing efficiency in Burn:x-wiley:07403194:media:MRM22182:tex2gif-stack-1 generation (hertz/watt) and increasing spectral bandwidth result in dramatic increases in power deposition and increased chemical shift registration artifacts for conventional gradient‐based in‐plane localization. In this work, we describe a novel method using radiofrequency shimming and an eight‐element transceiver array to generate a Burn:x-wiley:07403194:media:MRM22182:tex2gif-stack-2 field distribution that excites a ring about the periphery of the head and leaves central brain regions largely unaffected. We have used this novel Burn:x-wiley:07403194:media:MRM22182:tex2gif-stack-3 distribution to provide in‐plane outer volume suppression (>98% suppression of extracerebral lipids) without the use of gradients. This novel Burn:x-wiley:07403194:media:MRM22182:tex2gif-stack-4 distribution is used in conjunction with a double inversion recovery method to provide suppression of extracerebral resonances with T1s greater than 400 ms, while having negligible effect on metabolite ratios of cerebral resonances with T1s > 1000 ms. Despite the use of two adiabatic pulses, the high efficiency of the ring distribution allows radiofrequency power deposition to be limited to 3‐4 W for a pulse repetition time of 1.5 sec. The short echo time enabled the acquisition of images of the human brain, displaying glutamate, glutamine, macromolecules, and other major cerebral metabolites.

Details

show
hide
Language(s):
 Dates: 2010-01
 Publication Status: Published in print
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.22182
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Wiley-Liss
Pages: - Volume / Issue: 63 (1) Sequence Number: - Start / End Page: 9 - 19 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149