Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Maximising BOLD sensitivity through automated EPI protocol optimisation

Volz, S., Callaghan, M. F., Josephs, O., & Weiskopf, N. (2019). Maximising BOLD sensitivity through automated EPI protocol optimisation. NeuroImage: Clinical, 189, 159-170. doi:10.1016/j.neuroimage.2018.12.052.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
Volz_2018.pdf (Preprint), 4MB
Name:
Volz_2018.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
Volz_NeuroImage_2019.pdf (Verlagsversion), 4MB
Name:
Volz_NeuroImage_2019.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Volz, Steffen1, 2, Autor           
Callaghan, Martina F.2, Autor
Josephs, Oliver2, Autor
Weiskopf, Nikolaus1, 2, Autor           
Affiliations:
1Department Neurophysics (Weiskopf), MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_2205649              
2Wellcome Centre for Human Neuroimaging, Institute of Neurology, University College London, United Kingdom, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Gradient echo echo-planar imaging (GE EPI) is used for most fMRI studies but can suffer substantially from image distortions and BOLD sensitivity (BS) loss due to susceptibility-induced magnetic field inhomogeneities. While there are various post-processing methods for correcting image distortions, signal dropouts cannot be recovered and therefore need to be addressed at the data acquisition stage. Common approaches for reducing susceptibility-related BS loss in selected brain areas are: z-shimming, inverting the phase encoding (PE) gradient polarity, optimizing the slice tilt and increasing spatial resolution. The optimization of these parameters can be based on atlases derived from multiple echo-planar imaging (EPI) acquisitions. However, this requires resource and time, which imposes a practical limitation on the range over which parameters can be optimised meaning that the chosen settings may still be sub-optimal. To address this issue, we have developed an automated method that can be used to optimize across a large parameter space. It is based on numerical signal simulations of the BS loss predicted by physical models informed by a large database of magnetic field (B0) maps acquired on a broad cohort of participants. The advantage of our simulation-based approach compared to previous methods is that it saves time and expensive measurements and allows for optimizing EPI protocols by incorporating a broad range of factors, including different resolutions, echo times or slice orientations. To verify the numerical optimisation, results are compared to those from an earlier study and to experimental BS measurements carried out in six healthy volunteers.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2018-12-232018-09-112018-12-242018-12-262019-04-01
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1016/j.neuroimage.2018.12.052
PMID: 30593904
Anderer: Epub ahead of print
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden: ausblenden:
Projektname : Taking imaging into the therapeutic domain: Self-regulation of brain systems for mental disorders / BRAINTRAIN
Grant ID : 602186
Förderprogramm : Funding Programme 7
Förderorganisation : European Commission (EC)
Projektname : -
Grant ID : 091593/Z/10/Z
Förderprogramm : -
Förderorganisation : The Wellcome Centre for Human Neuroimaging

Quelle 1

einblenden:
ausblenden:
Titel: NeuroImage: Clinical
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 189 Artikelnummer: - Start- / Endseite: 159 - 170 Identifikator: ISSN: 2213-1582
CoNE: https://pure.mpg.de/cone/journals/resource/2213-1582