Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Qualitative improvement of resolution in high-resolution proton magnetic resonance in solids

Haeberlen, U., Sagnowski, S. F., Aravamudhan, S., & Post, H. (1977). Qualitative improvement of resolution in high-resolution proton magnetic resonance in solids. Journal of Magnetic Resonance, 25(2), 307-314. doi:10.1016/0022-2364(77)90025-7.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
JMagnReson_25_1977_307.pdf (beliebiger Volltext), 489KB
 
Datei-Permalink:
-
Name:
JMagnReson_25_1977_307.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt (Max Planck Institute for Medical Research, MHMF; )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:
externe Referenz:
https://doi.org/10.1016/0022-2364(77)90025-7 (beliebiger Volltext)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Haeberlen, Ulrich1, Autor           
Sagnowski , S. F., Autor
Aravamudhan, Sriram2, Autor           
Post, Hans2, Autor           
Affiliations:
1Research Group Prof. Dr. Haeberlen, Max Planck Institute for Medical Research, Max Planck Society, ou_1497739              
2Max Planck Institute for Medical Research, Max Planck Society, ou_1125545              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: By increasing the pulse rate in WHH-type multiple-pulse sequences we have succeeded in qualitatively improving the resolution in high-resolution proton magnetic resonance (PMR) spectroscopy in solids. WHH-type sequences are characterized by pulse spacings τ and 2τ, and we are now able to operate a 90 MHz multiple-pulse spectrometer with τ = 2 μsec. The gain in resolution is demonstrated by showing multiple-pulse FT spectra of single-crystal spheres of ferrocene and malonic acid. These spectra also demonstrate the substantial enhancement of the signal-to-noise ratio which naturally results from enhanced resolution. Preliminary results obtained at 270 MHz are also reported.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 1976-06-101977-02
 Publikationsstatus: Erschienen
 Seiten: 8
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1016/0022-2364(77)90025-7
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of Magnetic Resonance
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: San Diego [etc.] : Academic Press
Seiten: - Band / Heft: 25 (2) Artikelnummer: - Start- / Endseite: 307 - 314 Identifikator: ISSN: 0022-2364
CoNE: https://pure.mpg.de/cone/journals/resource/954922651175_1