  Microfluidic Chips for In Situ Crystal X-ray Diffraction and In Situ Dynamic Light Scattering for Serial Crystallography

Gicquel, Y., Schubert, R., Kapis, S., Bourenkov, G., Schneider, T., Perbandt, M., et al. (2018). Microfluidic Chips for In Situ Crystal X-ray Diffraction and In Situ Dynamic Light Scattering for Serial Crystallography. Journal of Visualized Experiments, (134): e57133. doi:10.3791/57133.

Item is

Files

show Files
hide Files
:
Gicquel.pdf (Publisher version), 2MB
Name:
Gicquel.pdf
Description:
Video Article
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
This article is Open Access.
:
SI1_chip_geometry.dwg (Supplementary material), 6MB
Name:
SI1_chip_geometry.dwg
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
image/vnd.dwg / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-
:
SI2_goniometer_adapter.stl (Supplementary material), 7KB
Name:
SI2_goniometer_adapter.stl
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/vnd.ms-pki.stl / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-
:
SI3_xds.sh (Supplementary material), 12KB
Name:
SI3_xds.sh
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/x-sh / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-
:
SI4_xscale.sh (Supplementary material), 854B
Name:
SI4_xscale.sh
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/x-sh / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-
:
SI5_ISigma.sh (Supplementary material), 264B
Name:
SI5_ISigma.sh
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/x-sh / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-
:
SI6_Rmeas.sh (Supplementary material), 496B
Name:
SI6_Rmeas.sh
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/x-sh / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-
:
SI7_rotation_matrix.sh (Supplementary material), 2KB
Name:
SI7_rotation_matrix.sh
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/x-sh / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show
hide
Locator:
https://www.jove.com/video/57133 (Publisher version)
Description:
Video Article
OA-Status:

Creators

show
hide
 Creators:
Gicquel, Yannig1, Author
Schubert, Robin1, Author
Kapis, Svetlana1, Author
Bourenkov, Gleb1, Author
Schneider, Thomas1, Author
Perbandt, Markus1, Author
Betzel, Christian1, Author
Chapman, Henry N.1, Author
Heymann, Michael2, Author           
Affiliations:
1external, ou_persistent22              
2Schwille, Petra / Cellular and Molecular Biophysics, Max Planck Institute of Biochemistry, Max Planck Society, ou_1565169              

Content

show
hide
Free keywords: Chemistry, Issue 134, in situ X-ray diffraction, fixed target, serial millisecond crystallography, microfluidics, protein crystallization, in situ dynamic light scattering
 Abstract: This protocol describes fabricating microfluidic devices with low X-ray background optimized for goniometer based fixed target serial crystallography. The devices are patterned from epoxy glue using soft lithography and are suitable for in situ X-ray diffraction experiments at room temperature. The sample wells are lidded on both sides with polymeric polyimide foil windows that allow diffraction data collection with low X-ray background. This fabrication method is undemanding and inexpensive. After the sourcing of a SU-8 master wafer, all fabrication can be completed outside of a cleanroom in a typical research lab environment. The chip design and fabrication protocol utilize capillary valving to microfluidically split an aqueous reaction into defined nanoliter sized droplets. This loading mechanism avoids the sample loss from channel dead-volume and can easily be performed manually without using pumps or other equipment for fluid actuation. We describe how isolated nanoliter sized drops of protein solution can be monitored in situ by dynamic light scattering to control protein crystal nucleation and growth. After suitable crystals are grown, complete X-ray diffraction datasets can be collected using goniometer based in situ fixed target serial X-ray crystallography at room temperature. The protocol provides custom scripts to process diffraction datasets using a suite of software tools to solve and refine the protein crystal structure. This approach avoids the artefacts possibly induced during cryo-preservation or manual crystal handling in conventional crystallography experiments. We present and compare three protein structures that were solved using small crystals with dimensions of approximately 10-20 µm grown in chip. By crystallizing and diffracting in situ, handling and hence mechanical disturbances of fragile crystals is minimized. The protocol details how to fabricate a custom X-ray transparent microfluidic chip suitable for in situ serial crystallography. As almost every crystal can be used for diffraction data collection, these microfluidic chips are a very efficient crystal delivery method.

Details

show
hide
Language(s):
 Dates: 2018-04
 Publication Status: Published online
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: ISI: 000444051300047
DOI: 10.3791/57133
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Visualized Experiments
  Other : Journal of Visualized Experiments: JoVE
  Abbreviation : J. Vis. Exp.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Rockville Pike, Bethesda MD : JoVE
Pages: - Volume / Issue: (134) Sequence Number: e57133 Start / End Page: - Identifier: ISSN: 1940-087X
CoNE: https://pure.mpg.de/cone/journals/resource/1940087X