Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Quantitative measurement of combustion gases in harsh environments using NDIR spectroscopy.

Niklas, C., Bauke, S., Müller, F., Golibrzuch, K., Wackerbarth, H., & Ctistis, G. (2019). Quantitative measurement of combustion gases in harsh environments using NDIR spectroscopy. Journal of Sensors and Sensor Systems, 8(1), 123-132. doi:10.5194/jsss-8-123-2019.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
3030683.pdf (Verlagsversion), 4MB
Name:
3030683.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Niklas,, C., Autor
Bauke, S., Autor
Müller, F., Autor
Golibrzuch, K.1, Autor           
Wackerbarth, H., Autor
Ctistis, G., Autor
Affiliations:
1Department of Dynamics at Surfaces, MPI for biophysical chemistry, Max Planck Society, ou_578600              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: The global climate change calls for more environmentally friendly use of energy and has led to stricter limits and regulations for the emissions of various greenhouse gases. Consequently, there is nowadays an increasing need for the detection of exhaust and natural gases. This need leads to an ever-growing market for gas sensors, which, at the moment, is dominated by chemical sensors. Yet, the increasing demands to also measure under harsh environmental conditions pave the way for non-invasive measurements and thus optical detection techniques. Here, we present the development of two optical detection systems using non-dispersive infrared absorption spectroscopy (NDIR). One system is intended for civilian use, capable of detecting both CO as well as CO2 in the range of 4–5 µm. Furthermore, restrictions regarding size and economic viability are put on this sensor so it can compete with existing sensors. For CO2, an estimated resolution of 444 ppm is achieved, which is competitive with established sensors on the market. For CO an estimated resolution of 1401 ppm was achieved, rendering it necessary to improve this sensor to be competitive with other available sensors. The second system is used in an exhaust system and is capable of detecting CO2 at 3.2 µm facing cross-sensitivity with H2O. A data analysis method is described to separate the CO2 and H2O signals, revealing a time resolution of 33 µs.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2019-03-01
 Publikationsstatus: Online veröffentlicht
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.5194/jsss-8-123-2019
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of Sensors and Sensor Systems
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 8 (1) Artikelnummer: - Start- / Endseite: 123 - 132 Identifikator: -